More confi dence into measuring results originates from the fact that fi lling errors are detected more reliably as PEM allows monitoring the condition of the measuring cell. As a consequence, erroneous results due to bubbles or particles in the fi lled-in sample are eliminated. More certainty means more confi dence.
The FillingCheck™ function makes it possible to detect fi lling errors, also in metallic U-tube oscillators. This is also valid for measurements up to 150°C. Detecting fi lling errors allows avoiding them.
Table 1. Sample changers and their respective properties. Type
Xsample 320
Xsample 330
Xsample 340
Xsample 520
Figure 2. The family of Anton Paar benchtop density meters and the portable DMA 35.
The Silent Assistants That Never Get Tired
With a sample fi lling device, be it a single or a multiple sample fi lling unit, the workload of the operator is made signifi cantly easier. Productivity, quality and repeatability of measurement results can be enhanced. While one sample is being fi lled and measured by the respective instrument(s), the operator can dedicate the time to other tasks such as preparing the next sample to be fi lled and analysed. Filling conditions are exactly identical and not subject to human infl uences. Time can be saved and cross contamination minimised as most fi lling devices provide automatic cleaning and drying procedures. The quality can be monitored even more closely as samples can be determined around the clock - a multi-sample changer never gets tired!
Depending on the requirements, several options of Xsample sample changers offer improved automatic fi lling. Table 1 gives an overview of their characteristic features.
The single sample units Xsample 320 and Xsample 330 allow automatic fi lling by means of a peristaltic pump. Single samples with higher viscosities that are best introduced with a syringe can be accommodated with the Xsample 340 single sample device. Up to two cleaning agents avoid carry-over if samples with different properties are fi lled in succession. Xsample 610 allows effortless fi lling of heavy duty single samples. With temperatures up to 95°C, highly viscous samples and even samples that are solid at room temperature can be handled.
For unattended fi lling of multiple samples 24 hours a day, Xsample 520 is well-suited for similar samples that are measured consecutively when sample recovery is not necessary. In case of different samples, Xsample 530 scores with up to three cleaning liquids to avoid cross contamination, with moderate maintenance requirements, robust design and high resistance to chemicals. Xsample 530 distinguishes itself with its optional sample recovery – no sample goes down the drain, no money is wasted.
Xsample 630 holds the pole position among the Xsample family for multiple samples and offers everything you could possibly ask for. Improved heating to temperatures up to 95°C and short heating periods result in enormous time savings. Xsample 630’s increased performance in magazines with up to 56 positions allows measurements of challenging petrochemical samples, waxes, food, and fl avour samples according to ASTM standards.
Xsample 530
Xsample 610
Xsample 630
Sample fi lling
Single from vial Single from vial
Single with
syringe
Multiple from vial Up to 96
Magazine positions
n/a n/a
Max. sample viscosity
3,000 mPa.s
3,000 mPa.s
n/a
36,000 mPa.s
3,000 mPa.s
Multiple from vial Up to 154 36,000
mPa.s
Single with
syringe
Multiple from vial Up to 56
n/a
10,000 mPa.s at 95°C
36,000 mPa.s at 95°C
Samples per hour
30 15
Sample recovery
No Yes
Automatic cleaning & drying
No Yes
(2 cleaning agents)
Yes 12 30 No No 16 Optional
(2 cleaning agents)
No
Yes (up to 3 cleaning agents
Yes 8 No
(2 cleaning agents)
8 No
Yes (up to 3 cleaning agents)
An Amazingly Wide Range of Applications
Be it the chemical industry, alcoholic and non-alcoholic beverages, pharma and petro industries, density measurement nowadays serves as a means of fast and reliable quality control worldwide.
Density measurement is helpful at all stages of production to determine the quality of incoming raw materials, to monitor the manufacturing progress all the way to the fi nal product where density measurement ensures that only product with the correct composition is delivered to the end user or consumer. The sugar content of soft drinks, the concentration measurement of sulphuric acid, the state of charge of batteries, the right composition to fulfi l the standards required for biodiesel, the conversion of volume-to-weight for products quantifi ed by weight while the products are fi lled, paid and even taxed by their volume, and the concentration of salt solutions for roads and pathways to help commuters in the wintertime to arrive safely at their fi nal destination are only a few examples.
Density meters, with or without a suitable fi lling device, can be combined with other measuring instruments or modules for the simultaneous determination of multiple parameters. In these measuring systems, usually a DMA M density meter acts as the master instrument that gets commands from a PC and forwards them to the respective instruments or modules. The combination of instruments for analysing the required parameters leads to custom-tailored measurement solutions for many industries.
A Modulyzer, the combination of a DMA 4500 M density meter, an Abbemat 550 refractometer, an MCP polarimeter, rounded off with an Xsample 530 multiple sample changer, represents an acknowledged measuring system, especially for the fl avour and fragrance industry as valuable sample can be recovered. With this system, the density, refractive index, and optical rotation can be measured simultaneously. A Modulyzer is shown in Figure 3.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124