search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
Lightpath Webview:Layout 1 23/4/10 14:26 Page 1


LABORATORY PLANNING SOLUTIONS HEMCO


®


Laboratory Planning


ISO 9001:2015 Certifi ed Company SEFA Certifi edVisit: HEMCOcorp.com


SAMPLE CELLS ‘Your Spectroscopy Specialist’ Solutions


UniFlow SE AireStream Laboratory Fume Hoods Unitized Superstructure for total chemical resistance Full line of Laboratory Cabinets & Epoxy Worksurfaces


UV-VIS-NIR-IR SAMPLE CELLS FOR USE WITH ALL TYPES OF SPECTROMETERS & FLUORIMETERS


www.lightpathoptical.com


WEBSITE ADVERTISING


TO ADVERTISE YOUR WEBSITE PLEASE CONTACT:


SALES@INTLABMATE.COM Transforming TB testing with advanced pipette controllers


Antrum Biotech, a healthcare innovations company dedicated to developing rapid diagnostic tools for diseases such as tuberculosis (TB), has integrated serological pipette controllers from Integra Biosciences into its laboratories. The pipetting aids have become an invaluable asset in the company’s liquid handling workfl ows, streamlining the commercialisation of a variety of innovative healthcare products that will have a lasting impact on how we diagnose and control disease.


‘Your Spectroscopy Specialist’


Antrum Biotech, located at Groote Schuur Hospital in Cape Town, South Africa, is a small start-up focused on translating scientifi c research into point-of-care diagnostic tests. The organisation specialises in respiratory and infectious diseases, and recently developed the IRISA-TB™ assay – a novel diagnostic test for detecting extrapulmonary TB (EPTB) – in response to shortfalls in current testing methods.


UV-VIS-NIR-IR SAMPLE CELLS FOR USE WITH ALL TYPES OF SPECTROMETERS & FLUORIMETERS


www.lightpathoptical.com


The company acquired a PIPETBOY pro pipette controller to improve the effi ciency of its liquid handling workfl ows, as Robbyn Mattei, Laboratory Scientist at Antrum Biotech, explained: “Bringing new diagnostic tools to market can be a notoriously slow and challenging process, but one way to accelerate product development is by investing in effi cient and reliable laboratory equipment. Introducing the PIPETBOY pro to our laboratory transformed the speed and accuracy of our liquid handling steps, allowing us to achieve a new level of precision in handling samples, buffers and solutions for our research projects, while also saving us valuable time.”


UV-VIS-NIR-IR


“The PIPETBOY pro is lightweight, stable and easy to control, and the unique LED light feature is also useful, especially when we are trying to aspirate and dispense accurate liquid volumes in more dimly lit spaces. The pipette controller is also available in many different colors, allowing us to assign specifi c devices to different tasks or workstations in the lab to prevent contamination within our protocols. We highly recommend the PIPETBOY pro to any lab seeking to optimise its operations and achieve exceptional results,” Robbyn concluded.


SAMPLE CELLS FOR


USE WITH ALL TYPES OF SPECTROMETERS & FLUORIMETERS


www.lightpathoptical.com


Visit the Integra Biosciences website to fi nd out how the PIPETBOY pro pipette controller is accelerating the commercialisation of innovative healthcare products. More information online: ilmt.co/PL/KYdE


‘Your Spectroscopy Specialist’ 61959pr@reply-direct.com IR hotplate/stirrer delivers superior heating and mixing


The latest infrared heating technology has been used in the design of the WH280-NH hotplate-stirrer from Wiggens. Thanks to this radiation heating technology, the Wiggens WH280-NH can be used for rapid heating up of various shaped vessels, including round-bottom fl asks, and the solution inside can be heated up to a maximum of 450°C in a very short time.


The new Wiggens hotplate stirrer enjoys the benefi ts of a Schott glass ceramic surface with exceptional chemical resistance, a high surface quality, and a resistance to temperature shocks of more than 700°C, providing users with an optimal solution compared to conventional heating surface materials. The poreless smooth surface enables even the most stubborn dirt to be easily cleaned. The high infrared permeability ensures that the heating energy is transferred quickly and with very limited loss, therefore, it heats liquids fast and saves time and energy. Intelligent Cascade Control enables self-optimising to reach perfect temperature stability. If the Pt-100 sensor is connected, temperature-controlled work with stability of +/- 2°C can be reached in most applications.


In addition to rapid heating capability and superior temperature control, the WH280-NH also offers well controlled gentle to intense mixing of liquids, and is also suitable for large volume viscous media.


The stirring and heating can be controlled separately by convenient turning knobs. All functions can be viewed and monitored on a bright touch screen, including most


frequently used parameters, such as, working temperature, stirring speed, working time, and safety temperature. Memory function for stirring speed and temperature setting makes it convenient to start the experiments with fi xed conditions. A residual-heat display protects the users from burning their hands.


With the aforementioned benefi ts, and many other features, the Wiggens hotplate stirrer is the optimal solution for heating and mixing of liquids in labs, for gentle to intense applications. More information online: ilmt.co/PL/gP3P and ilmt.co/PL/Q2Qe


59072pr@reply-direct.com


Index of Advertisers Achema 2024


47


Anton Paar GmbH Astell Scientifi c Ltd Biopharma Group


Integra Biosciences AG JSB Group


Julabo GmbH


Kern & Sohn GmbH Kottermann GmbH


56, OBC 36 21 19 9


29


OFC, 40 50, 51


CONSUMABLES & SPARE PARTS


CALIBRATION & REPAIR INSTRUMENTS


Kyoto Electronics Manufacturing Co Ltd


Labtech Srl


Memmert GmbH Myron L Company Nuaire Inc


Oxford Instruments


25 30 53 31 35 13


Peter Huber Kältemaschinenbau AG 43 Plas Labs Inc


37


Pope Scientifi c Inc Scharlab Sl


SEAT Ventilation SAS Shimadzu Europa GmbH Starna Ltd


Teledyne FLIR VICI AG


Wiggens Technology (Beijing) Co, Ltd


23 49 39


IFC 15 41 7


57


INTERNATIONAL LABMATE - APRIL 2024


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68