Drug Discovery, Pharmaceuticals & Cannabis Testing
Summary
With the Rapid Small-Scale Oxidation Test, the RapidOxy 100 offers a quick, easy, and reliable method to investigate formulas and products containing cannabinoids with regards to oxidation stability and product quality. The unique measuring principle leads to a signifi cantly reduced measuring time for the described investigations. Additionally, the straightforward principle gives rise to many further possibilities to access the oxidative behaviour of samples. By evaluating the pressure/time curve with OxyLogger 100 further, you can conduct automatic calculations of consumption, activation energy, and much more. Major benefi ts are its ease of use and fully automatic measurements. Since weighing in the sample is the only manual step, you minimise error sources as well. Independent from sample consistency, no sample preparation is necessary prior to the measurement. Therefore, you can investigate the oxidative behaviour of a sample as a whole.
References 1. Difonzo G., et al. 2018. Food Research International, 108: 48–56.
2. Guitard, R., Nardello-Rataj, V.*, Aubry*, J.M. 2016. International Journal of Molecular Science, 17: 1220.
3, H82IA016EN-A (Chia Seed Oil)
https://www.anton-paar.com/corp-en/services-support/ document-fi nder/application-reports/oxidation-stability-of-chia-seeds/
4. Edinger, C. 2023, Oils and Fats International, 39: 40.
5. H82IA008EN-A (Cocoa Mass)
https://www.anton-paar.com/corp-en/services-support/ document-fi nder/application-reports/oxidation-stability-of-cocoa-mass-and-vanilla-extracts/
6. XPAIA136EN-A (Food Powder)
https://www.anton-paar.com/corp-en/services-support/ document-fi nder/application-reports/ebook-mfi -food-powders-fi eld-guide-to-food-powder- characterization/
Read, Share and Comment on this Article, visit:
www.labmate-online.com Scalable fl ow method produces enantiomerically pure pharmaceutical intermediates
Researchers at Lilly SA have pioneered a ground-breaking continuous flow method for the Wadsworth–Emmons cyclopropanation of alkyl-substituted chiral epoxides into chiral cyclopropane carboxylic acids, as reported by Uniqsis.
Utilising a custom setup comprising the FlowSyn continuous flow reactor and binary pump, the researchers successfully devised a novel flow process that overcame challenges associated with high temperature, pressure, and the volatile nature of the epoxide starting material.
The FlowSyn flow reactor demonstrated heightened efficiency by maintaining a higher concentration of low-boiling-point reactants in the liquid phase, due to its reduced headspace, resulting in enhanced reactivity compared to batch methods employing sealed vessels.
Furthermore, the researchers integrated their cyclopropane formation process with in-line workup and hydrolysis transformations, yielding enantiomerically pure cyclopropane carboxylic acids in impressive yields of up to 100 grams.
Uniqsis’s FlowSyn, designed by a team of experienced flow chemists and engineers, stands as a fully integrated continuous flow reactor solution. Offering seamless reaction optimization and scale-up capabilities from milligrams to hundreds of grams, FlowSyn serves as a versatile tool for pharmaceutical intermediates production.
Read this paper in full:
ilmt.co/PL/xz4y More information online:
ilmt.co/PL/Ovpj
62360pr@reply-direct.com
Optimise lab-scale purifi cation with benchtop nutsche fi lter dryers
Pope Scientific leads the way in laboratory separation equipment with its proven Benchtop Nutsche Filter Dryers. These compact units have been a staple in laboratories for years, offering researchers a powerful tool for testing, piloting, and small-scale processing. Pharma, fine chemicals, cannabinoids, electronics, and specialty materials are just a few of the many applications.
Pope’s fully enclosed sanitary design provides numerous advantages over traditional, open Buchner funnel apparatus. Materials are contained and isolated from the user for maintenance of purity and safety. Featuring ASME-certified pressurisability, filtering and cake washing is faster than via vacuum. Drying of the solids is also performed in the nutsche, efficiently accomplished under vacuum and jacket heating, plus a raising/lowering cake agitator to break up lumps and churn the solids. This is the same operation as industrial nutsches, but smaller.
Pope’s Benchtop Nutsche Filter Dryers are stocked in 1, 3, 4, and 5-litre sizes. All come pre-tested and pre-fitted with essential components including valves, sight glasses, pressure relief, spray assembly, pressure/vacuum gauge, and a manual with full documentation package.
In addition to stocked units, Pope specialises in custom designed lab, pilot, and production nutsches in a wide range of sizes, features, and functionality, and are optimised to meet clients’ processing needs and preferences. Pope Scientific has your solution – get in touch today.
More information online:
ilmt.co/PL/V2Ed The Spotlight could be on you!
62305pr@reply-direct.com
Check our Media Information Pack for further details and send your Press Releases to
pr@intlabmate.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68