xvi UK Focus - Air Monitoring Automatic isokinetic sampler for reliable emissions testing


The EmiTest Iso is an automatic isokinetic sampler that ensures the accuracy and safety of emissions testing from CDL Tecora; it is compliant with a plethora of international testing methods, including EN13284-1, US EPA M5, USEPA M17, and ISO9096.


The EmiTest Iso is equipped with advanced features that ensure enhanced data quality and reliability, easier use on stack, time-saving, and worker safety. Its probe module, directly attached to the probe, manages the velocity measurement sensors, probe and box heating control, and angle measurement. The module’s main advantages are better accuracy of differential pressure measurement, a lighter umbilical cable, and a deported screen plugged on the probe module for remote sampler control.


The EmiTest Iso offers three modes: velocity measurement, isokinetic sampling, and constant fl ow sampling. All sensors can be calibrated in 5 points by the operator for optimal data quality. The instrument’s calibration reports are registered in memory. Additionally, it has a Pitot and stack library with over 100 capabilities, a leak test menu, user-customisable settings, and automatic autozero and functional checks during start-up.


The EmiTest Iso is equipped with industrial-class electronics and includes an independent and secured memory to avoid data loss. Internal check routines are performed


automatically to ensure good instrument functioning. The instrument casing is designed to be user-friendly and fi eld-proof. The EmiTest Iso’s features include sensors test mode with results saved in memory for better QA/QC management, angle measurement, swirl angle and wall factor measurement, stagnation


check, Pitot leak check, and a new leak test calculation. It also has a large choice of languages, the capability to set alarms, and a deported screen plugged on to the probe module for sampler remote control.


The instrument is user-friendly, equipped with a new ergonomic interface for data visualisation, large touchscreen buttons for use with gloves, and intuitive navigation. The EmiTest Iso has rapid connectors for smoother use, reduced cables for easier transportation and safety on the stack, and an optional deported screen for remote control of the sampler.


The EmiTest Iso can produce many reports, including exhaustive sampling reports, sensor test reports, sensor calibration reports, alarm reports, and continuous data acquisition with settable frequency. All data are recorded in .csv format in the large internal memory (16 GB) and can be downloaded on a USB stick. Reports can also be printed with an optional thermal printer.


ABB celebrates 85 years of the technology that revolutionized emissions monitoring


ABB celebrates 85 years of the technology that revolutionized gas analysis and emissions monitoring in chemical plants and refi neries, the pulp, paper and metal industries, power generation, cement, and others.


When launched in 1938, URAS was known as the fi rst “ultra red absorption recorder”, a continuous gas analyzer capable of instantly measuring the concentration of more than 100 gases through infrared spectroscopy.


“This technology was truly revolutionary from the day it was invented. Today, it is a benchmark for uncompromising environmental compliance. With URAS, numerous industrial companies around the world can monitor emissions and safeguard the environment,” said Ben Goossens, ABB Measurement & Analytics.


URAS is used by industrial companies around the world as a key solution for ensuring environmental compliance. With its unrivaled monitoring uptime, this technology is used in the continuous monitoring of gases that come out of industrial chimneys. It also measures emissions from marine vessels, helping shipping companies comply with environmental regulations.


As a continuous gas analyzer, URAS has a wide range of applications beyond the industrial segments – from helping save lives in hospitals by measuring the CO2 levels in diagnostic breath tests to supporting the process of ripening of bananas during shipment by analyzing the concentration of ethylene.


In 1996, URAS was used as a foundation in ABB’s groundbreaking Advance Optima modular analyzer, which unifi ed the operation for all types of gas analyzers in one single design. With this, URAS became the fi rst network analyzer with its own IP address. This was the beginning of the digitalization of analyzer technology.


“Decades before the Internet of Things, URAS communicated digitally. Today, it’s all about the digital transformation and this is where it all started,” said Ben Goossens.


URAS was created by German engineers Erwin Lehrer and Karl Friedrich Luft. In 1988, the technology was further improved by adding gas-fi lled calibration cells. Because it no longer needed high-pressure test gas cylinders, the cost of operation dropped signifi cantly and increased the ease of use.


More information online: ilmt.co/PL/mV0v For More Info, email:


email:


For More Info, email: email:


For More Info, email: email:


60795pr@reply-direct.com


For More Info, email: email:


For More Info, email: email:


For More Info, email: email:


Hiden Analytical develops and supplies instruments for a new era of process gas analysis from UHV to Atmospheric Pressure. The latest in the range of product showcase brochures, HPR-30 Series offers an insight into the range of instruments, sampling inlets and software packages.


The Hiden HPR-30 Series are bolt on vacuum process analysers designed for fast response, high sensitivity analysis of gas and vapour species. Equipped with Hiden’s multi-level software package, offering simple control of mass spectrometer parameters and complex manipulation of data and control of external devices. Applications include leak detection, contamination monitoring, process trend analysis and analysis of high mass species and precursors used in ALD and MOCVD. Standard mass range is 200 amu, versions up to 1000 amu are offered.


Optional upgrades include the innovative Hiden 3F series triple fi lter quadrupole system providing enhanced abundance sensitivity, part-per-billion (ppb) detection levels and high contamination resistance, particularly suited to the analysis of aggressive gases in CVD and RIE applications.


Multiple sampling confi gurations are offered to suit a full range of process pressure and vacuum system geometry requirements. Versions are offered with single, or multiple sampling inlets, either unheated or heated to allow sampling of volatile species.Systems are offered cart mounted, and with height adjustment for maximum compatibility between tools. For pulsed deposition processes, time resolved measurements are offered to 50 ns time resolution.The HPR-30 Series are designed to offer a fully featured, fl exible and powerful solution for the monitoring of parameters in all aspects of process gas analysis such as leak detection, vacuum quality and precursor monitoring.


For More Info, email: email:


IET ANNUAL BUYERS’ GUIDE 2023/24


For More Info, email: email:


59246pr@reply-direct.com 60340pr@reply-direct.com


A brochure for a new era in process gas analysis


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128