search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
40


Air Monitoring Real Time Monitoring Using Particulate Samplers


Ecotech (Australia) is pleased to announce the release of a real time particulate module for use with its range of particulate samplers. High Volume Air Samplers are designed to sample ambient air through a pre-weighed filter for 24 hours after which the filter is weighed and PM concentration calculated. While there are approved methods for semi-real time monitoring such as the Tapered Element Oscillating Microbalance (TEOM) and Beta Attenuation Monitors these instruments are costly, require significant maintenance as well as an air conditioned enclosures.


The real-time particulate module is combined with a high volume air sampler providing both instantaneous measurements of PM10 or PM2.5, along with compliance data collected by the sampler.


The HighVol 3000 high volume air sampler is U.S. EPA approved as a Reference Method for PM10 sampling and can also be fitted with a PM2.5 inlet. Combining it with the new Real Time Particulate Module enables near real time measurement of ambient PM concentrations to be measured and logged by the sampler. Measurements made by the real time monitor can be logged as one, five, ten, 15 or 30 minute averages.


The Real Time Module conditions air samples for RH then passes them through a forward light scatter laser nephelometer engine where the particulate mass is measured. A purge system protects the optics from excessive exposure to dust particles. The mass signal is continuously scaled to an analog voltage output which represents the real-time particulate concentration


The sampler can be fitted with a modem for remote downloading of data such as particulate concentration, flow, wind speed and direction. Gravimetric data calculated from weighing of the high volume samplers filter can be used to create a correlation factor for the real time monitor or can be used to backwardly correct data measured by the real time module.


 


  





CALIBRATION SOLUTIONS FOR EMISSIONS MONITORING


Calibration Gases to support EN 14181 compliance





Cylinder sizes to suit all applications





 


  Reader Reply Card no 107 


Complete range of supporting gas control equipment


New range of CryoSpec QAL3 gas mixtures





Engineering support and services


Binary and multi- component mixtures





Full range of ISO 17025 gases available


CODEL International (UK) have recently announced the launch of the “40 Series” of emissions monitors designed primarily for use on power generation plants and processes such as cement manufacture. These innovative analysers are based on a completely new design that has enabled CODEL to produce a compact, reliable and accurate product at a very competitive price.


This advanced new analyser may be configured into a single or multi-channel mode (up to 4 gases plus temperature and


pressure). The available gases are CO, CO2, SO2, H2O and HCL and each of these are obtainable alone (including gas


temperature) or in a number of combinations.


CryoService supply a complete range of calibration gases, manufactured to specific customer requirements for QAL2, QAL3 and AST, with fast delivery lead times.


www.cryoservice.co.uk


The main benefit of the “40 series” is the use of an in-situ stainless steel probe within the stack, this produces a neat design that does not require the ancillaries associated with extractive analysers (chillers, heated lines, sample pumps, analyser house etc.), this significantly lowers maintenance requirements and initial and on-going costs as well. The “40 Series” meets the requirements of EN14181 QAL 3 by injecting zero and span gases at regular intervals and producing the data required for the product ion of Control charts (CUSUM, Shewhart, and EWMA).


The electronics within the temperature controlled Sensor unit have been designed using surface mount technology to create a compact footprint and for ease of maintenance. The Sensor unit has an RS 485 output to the remote control unit which can be sited along distance from it. Where operators require an output in mg/Nm3


, the


CryoService Limited, Warndon Business Park, Worcester WR4 9RH Tel: 01905 758200 Fax: 01905 754060


G-CEM 4050/80/90 can provide this at the Control unit using the onboard temperature, pressure and moisture sensors.


Reader Reply Card no 106


New Series of Gas Analysers for Large Combustion Processes


Reader Reply Card no 108


Reader Reply Card no 109


Reader Reply Card no 110


IET


May/June 2010


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68