Flow Level Pressure Accurate flow rate measurement of viscous liquids
Titan Enterprises’ OG range of Oval Gear flowmeters provide the perfect solution for accurate measurement of the flow of viscous liquids and lubricating fluids. Unlike other flowmeters, measurement accuracy with oval gear devices actually improves as the liquid viscosity increases, from a nominal 1% to around 0.1% of flow rate at higher viscosities.
The OG range of oval gear flowmeters are compact, rugged and deliver unprecedented performance at a low cost of ownership. Available as standard with stainless steel or aluminium bodies, OG flowmeters are bidirectional and available in sizes from 1/4 to 2-inches (6 to 50 mm), for flows between 1ml/min and 500l/min. For applications involving measurement of corrosive or caustic fluids, versions of OG flowmeters with completely non-metallic wetted components (ceramic, PEEK™ and a choice of elastomer) are available. Over recent years, Titan Enterprises has expanded its OG flowmeter range and has supplied special application optimised OEM versions for use at elevated temperatures (200°C) or high pressure (950Bar). Models are also available certified as suitable for use in hazardous areas.
The standard inlet and outlet options for OG flowmeters are BSP or NPT, though alternative versions are available with flanges and female threads. The electronic pulse output signal is transmitted via TTL or contact closure.
Each OG flowmeter supplied by Titan Enterprises is individually flow calibrated and supplied with a traceable flow test certificate.
More information online:
ilmt.co/PL/xLW6 For More Info, email:
Multiphase level measurements for optimal process control
email: For More Info, email: email:
The monitoring of interfaces in process vessels can be very difficult due to extreme process conditions. Wherever other methods fail, a radiometric measurement method offers significant advantages. With Berthold’s EmulsionSENS, interfaces can be reliably detected with the aid of a density profile and the processes dependent on them, can thus be optimally controlled.
The measurement of several phases, so-called multiphase levels, poses some challenges for the manufacturers of process measuring instruments. These include, in addition to the often not distinctly formed interfaces, the (sometimes only slightly) different phase densities. Wherever a “live image” of the highly complex separation process in a vessel is required to adapt certain process parameters, multiphase level measurements are used. These include for example, separators, storage tanks, desalters, and hydrocracker.
These diverse applications underline that multiphase level measurements are often used in processes operating under extreme conditions, which makes radiometric measurements indispensable. The measuring principle of radiometry is based on the attenuation of radiation when penetrating materials. The detector measures the radiation emanating from the radioactive source and attenuated by the material in the vessel, whereby the resulting signal can be assigned to a corresponding measured value, such as a density value, by means of a calibration. The process is almost independent of other process conditions, such as vessel size, buildups or installations in the vessel.
With Berthold’s EmulsionSENS, the user has the opportunity to get a glimpse inside the process vessel and to monitor the interfaces formed therein. The EmulsionSENS multiphase level measurement system consists of a combination of high sensitivity scintillation detectors and low activity gamma sources located along the desired measurement range. Based on the principle of radiometry and a corresponding calibration, each detector delivers an individual local density value, which can be forwarded via HART signal to a process control system supplied by the customer and used to create a density profile over the entire measuring range. The figure shows schematically the measuring principle of EmulsionSENS for a desalter and the resulting density profile. By mounting the detectors on the outer wall of the vessel, these are easily accessible and adjustable. A one-time calibration of the system as part of the initial commissioning is sufficient, a recalibration is not required. Since neither mechanically moving parts are installed, nor do the sensors come in contact with the material to be measured, radiometric systems are wear-resistant and maintenance-free. Due to the curved dip tube, which is used to position the encapsulated sources, the length of the measurement path at each position is almost the same (<500 mm) and as much measured material as possible is recorded, allowing a representative measurement and imaging of the density profile. Both the long measuring path and the use of high-energy gamma sources (e.g. Cs-137) make the measuring process insensitive to buildups on the container wall and the dip tube. Because the shield is mounted on the vessel, the sources can be removed from the dip tube for example for maintenance work and stowed safely, so from the point of view of radiation protection, safe entry of the vessel can be guaranteed.
In addition, EmulsionSENS offers the possibility to connect an evaluation unit. Based on the created density profile, this unit uses internal algorithms to determine the position of the individual interfaces and provides these as 4 ... 20 mA current signals, in addition to the individual density values of the detectors. The evaluation unit not only offers the advantage of redundancy, but also displays the measured values in real time. Bar graphs and time histories of the phase densities enable the user to quickly gain an overview of his desalter, thus enabling the adaption of important control parameters (e.g. dwell time or chemical addition).
For the measurement of interfaces, radiometric measuring systems compared to other methods, such as capacity, differential pressure or radar measurements, offer some obvious benefits that justify the use of radioactive sources. In the chemical and petrochemical industries, aggressive atmospheres, high pressure, and extreme temperature processes require technology that can withstand these harsh conditions while delivering accurate results. Radiometric measuring systems impress and convince with their non-contact, reliable and robust operation. The measurement of interfaces under extreme conditions is therefore an ideal application example for radiometric measurement systems, such as Berthold’s EmulsionSENS.
More information onine:
ilmt.co/PL/o0yB For More Info, email:
email: For More Info, email: email:
50652pr@reply-direct.com XINjIaNg BuILds fIRsT EThyLENE PROjECT TO PROMOTE PETROChEMICaL INdusTRy aNd BOOsT REgIONaL ECONOMy
The regional government of Northwest China’s Xinjiang Uyghur Autonomous has launched its first ethylene production project, a core substance needed in oil refining, in a move that will drive local economy and increase employment. The project, with an investment of 9 billion yuan ($1.3 billion) from China National Petroleum Corp (CNPC), China’s leading oil and gas corporation, is the largest investment in refining and chemicals the company made in southern part of the region. Source: Global Times
50460pr@reply-direct.com
47
OCTOBER / NOVEMBER •
WWW.PETRO-ONLINE.COM
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52