search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
Analytical Instrumentation 15


DANI Master TOF High Troughput GC-MS


When productivity is the name of the game, MASTER-TOF MS is the answer.


This new and compact GC-TOF-MS system enables the automated and unattended processing of large numbers of samples per day. In


combination with the autosampler up to 160 samples can be analysed sequentially.


The fast acquisition rate (1000 spectra/s) and the widest linear dynamic range (105) guarantee high throughput analysis. These features, in combination with powerful data processing supported by an original deconvolution algorithm, result in a reliable identification of trace compounds even in complex matrices.


The combination with GC x GC, offers the high throughput of the TOF with the high resolving power of 2D GC, ideal for fingerprinting acquisition in the petro industry.


Reader Reply Card No 56


DANI Instruments Solutions


The top of the line is the bench-top MASTER - TOF system, that in combination with the Master -GC and Master -AS provides a solution for fast and ultra-fast data acquisition of complex samples.


A Dynamic approach to high sensitivity Headspace analysis is based on the MASTER DHS. No cross contamination in the analysis of VOC’s from a variety of matrices, Q-C- analysis or biomonitoring.


The combination of different analysis tools guarantees continuation in operation using the same software lay-out.


Combinations with Master TD (thermal desorber) and Master Air Sampler are also offered.


The MASTER -GC can be configured for NGA, RGA, hydrocarbons, Biodiesel analysis, TOGA, LPG analysis and applications according to ASTM 4815 and ASTM 5580.


Reader Reply Card No 57


SpiralTOF JMS-S3000


This new ultra-high resolution MALDI-TOFMS system incorporates an innovative SpiralTOF ion optical system. Different combinations with MS-MS and linear TOF, exploits full capabilities of this innovative mass spectrometer.


In the linear configuration synthetic polymers can be observed up to 200 kD. Also for copolymer analysis this SpiralTOF will offer a simple solution.


The system has a very high resolution over a large m/z range.


In the MS/MS mode, we can take advantage of the high precursor ion selectivity to generate “clean spectra”. In the HE-CID only mono-isotopic ions will be observed.


Reader Reply Card No 58 FEATURES JMS-T100GCv:


• Stable high sensitivity and resolution • High resolution at any time • Mass measurement with easy operation • High speed data acquisition • Unique EI/FI/FD ion source • Compatible with LIFDI & GC x GC • Direct probes are available • EI, PCI/NCI standard available • Attractive price/quality ratio


www.jeolbenelux.com or sales@jeolbenelux.com Reader Reply Card No 59 February / March 2011 • www.petro-online.com & JOIN FORCES in mass spectrometry


Master TOF Time of Flight GC/MS


FEATURES Master TOF: • High throughput • Extremely compact design • Powerful software solution • Full automation with autosampler • Enhanced sensitivity • Ideal solution for Fast GC and GC x GC • Compatible with Dynamic Headspace Sapmpler and - Thermal Desorber.


• Innovative Master Lab Software for quantitative/qualitative analysis and deconvolution to handle complex samples


• Easy maintenance GC-TOF with Dedicated FD/FI Source


This new GC-TOF system JMS-T100GCv provides multiple capabilities in a single instrument. The high-end TOF MS system combines high resolution and high dynamic range with a variety of different ion sources.


The FD/FI method is a very interesting method for checking molecular weights via soft ionisation. The standard EI/CI source can be exchanged with a dedicated FD/FI source, to perform standard FD work for non-volatile compounds or FI work in combination with a GC column.


No need to change anything when switching from FD to FI, since the GC-capillary is already in place.


This combination source is extremely interesting in the field of petro-chemistry (crude oils etc) and in the field of polymers for average molecular weight measurements.


Reader Reply Card No 55


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52