72 INTERIORS


perspective, these are not always ideal as the surface of the button or plate needs to be cleaned regularly to prevent the spread of germs. Instead, contact free sensors can be utilised that use microwave detection for activation. These controls allow doors to be opened by the simple motion of a hand in front of the sensor, with no contact required.


Despite the advantages of automatic


doors, there will be places within a building where it is not possible or even desirable to adopt this method. Here, manually operated doors can be made more hygienic by specifying door hardware with anti-microbial properties. Products that feature a silver-ion based anti-microbial finish will inhibit the growth of bacteria by disrupting the key cell functions. Although the hardware will still need to be cleaned regularly, as with any surface in the building, this finish will help limit the spread of potentially harmful bacteria. Furthermore it is also worth considering measures to reduce interaction with doors as they move through the building. The fire regulations and the building’s compartmentation strategy may dictate the need for fire doors in certain locations, however there are solutions that allow compliance to be achieved in a way that minimises physical interaction and improves ease of movement.


Electro-magnetic hold-open or free-swing door solutions can be specified in place of standard fire door closers. These allow doors to remain open during regular use but will automatically close the door upon activation of a fire alarm or in the event of a power failure.


This will ensure the doors will still function as designed in the event of a fire, to minimise the spread of flames and smoke. The added advantage of these solutions for hospital buildings is that it aids the free movement of beds and wheelchairs, especially through corridors.


Access control


In healthcare environments, securing certain areas of the building is essential to ensure the safety of staff and patients and prevent unauthorised access to sensitive areas. In certain facilities, such as those that offer mental health or dementia care, a level of access control may have to be maintained for the entire building. Traditional cylinder locks or coded keypads are commonly used as simple methods of preventing unauthorised access. However, the physical contact required to


WWW.ARCHITECTSDATAFILE.CO.UK


use these locks can allow germs to spread if not maintained properly. To improve hygiene, digital equivalents that support contactless access can be specified instead of conventional locks, and keypads can be exchanged for card readers. There are a range of options to suit all types of doors and locks as well as a variety of radio-frequency identification (RFID) access media. There are also products that feature Bluetooth low energy (BLE) capabilities to enable smartphones to function as access media devices.


These digital systems have additional advantages in terms of convenience and control for the client and facility. The individual readers can often be integrated into a single system to provide greater control of access rights, which can often be managed remotely. It also offers the ability to maintain a detailed log of access to key areas. Additionally, these access controls can be easily integrated with automatic door systems to minimise the physical contact required. Finally, for facilities that operate a time and attendance (T&A) system for logging and managing the presence of staff, traditional touch-operated interfaces can be replaced with one that offers a higher level of hygiene. The same RFID and BLE contact free technologies are also available for this application to further minimise the risk of germs and bacteria spreading. In specifying door and access control solutions for healthcare buildings, the access and security considerations must also be balanced with the need to make the environment as hygienic as possible. By choosing the correct, high quality systems, architects can ensure that these aims are achieved. Engaging with a specialist supplier that can provide a single point of contact to identify, evaluate and provide the most appropriate entrance systems and access solutions will help ensure the best possible advice and guidance is received.


Tim Checketts is head of specification at dormakaba


ADF JUNE 2021


Despite the advantages of automatic doors, there will be places within a building where it is not possible or even desirable to adopt this method


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84