22 APPOINTMENTS & NEWS


BRE publishes aluminium cladding system test


challenges. UK specifiers and building control officers who can no longer turn to desk top studies for reassurance on safety performance are now looking to the most accredited test houses to put in place live and strictly monitored fire tests. In addition, the September Guidance Circular to Heads of Local Authority Building Control Departments and Approved Inspectors requires that responsible officers must look for clear evidence to confirm that “satisfactory evidence has been submitted that the requirements of paragraph B4 of Schedule 1 are being met”. These amendments to the 2010 Building Regulations relating to 18 metre plus buildings require cladding to undergo a full scale test. The BRE’s fresh round of tests on Aluminium Cladding systems highlights the benefits of using a product with zero spread of flame characteristics. The innate fire safety qualities of aluminium have long been recognised and made it the go-to material in the provision of an efficient and attractive building envelope. But as


A


year after Grenfell the task of safeguarding tower block residents remains one of our greatest urban


tragically revealed at Grenfell, laminating it to petrochemical based structural substrates can result in disaster. In a newly published report, BRE testing


has shown that aluminium cladding, in this instance a 3mm aluminium cassette system from Fusion Facades, combined with intumescent fire stops around openings and between floors will actively provide fire protection to the building fabric and the residents within by effectively preventing the spread of a fire. Specifiers are directed to Report Number P110509-1001 Issue one BRE Global Classification Report. 18th June 2018. Fire performance test in accordance with BR 135:2013 Annex B Test method BS 8414- 2:2015 + A1:2017 The report shows in detail the results of a


fire test which featured 136mm thick MetSIP panels, 60mm thick Rockwool insulation, an 80mm cavity and 3mm Fusion Facades aluminium cassette panels. The test measured three specified critical parameters; • External fire spread • Internal fire spread • System burn through In all instances the system proved to be


compliant. The Fusion Facades aluminium cassettes remained firmly attached to the fixing system. With the exception of panels immediately above the combustion crib which were partially consumed, all the remaining panels suffered only discolouration of the coating. Critically there was no evidence of surface spread of flame. Mike McKee of Fusion Facades reports


that the company will stand ready to meet with Building Control Officers, specifiers and cladding contractors to enlarge on the details of the test and the reported results. “Our industry has a duty to assist


local authorities, housing associations and landlords on replacement products and new build projects at this time of heightened concern surrounding aluminium cladding. Industry professionals and tenant associations alike will find much to reassure them in the rigor and scope of the BRE test. The results have unequivocally confirmed our long held belief that well designed aluminium cladding systems present no danger and can, in effect add to the safety of the structure in the event of a fire”


01706 751400 www.fusionfacades.co.uk


WWW.ARCHITECTSDATAFILE.CO.UK


ADF NOVEMBER 2018


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84