Six practical tips you need to know about power products


Power supplies are normally regarded as simple animals and indeed they are – but with a little bit of thought you can get a lot more performance and functionality from the power supply that you’re using. Howard Peat, distribution sales manager – field sales engineer at Microlease and Martin Dinmore, distribution field engineer at Keysight Technologies, distill a lifetime’s experience of power supplies and power measurements into six quick, easy-to-apply tips


W


Tip 1: Use remote sensing to compensate for load-lead effects


hen a power supply leaves the factory, its regulation sense terminals are usually connected to the output terminals. This limits the supply’s voltage regulation abilities, even with very short leads. The longer the leads and the higher the wire gauge, the worse the regulation becomes. It gets even worse if relays are used to connect power to the load.


Remote sensing, where the sense terminals of the power supply’s internal feedback amplifier connect directly to the load, lets the power supply regulate its output at the load terminals rather than at its own output terminals. It is implemented by disconnecting local sense leads from the output terminals, then using twisted two- wire shielded cable to connect the power supply sensing terminals to the sense points on the load.


Tip 2: Eliminate noise from low- level measurements


It is easier to eliminate noise than to filter it. Starting with a low-noise supply is naturally a great way to keep noise out of your measurements. Switch-mode supplies can be used successfully if their specifications include a low (<20mA) common-mode current. The next areas to consider are connections between power supplies and the device under test. Here, conducted


Figure 2: A down programmer situated between power supply’s positive output and a negative source


the DUT’s impedance to ground from its plus and minus input terminals. Voltage spikes from the DUT can be


prevented by adding a bypass capacitor close to the load, which offers low impedance at the highest testing frequencies.


Tip 3: Use down programming to increase test speed


Figure 1: A down programming circuit with an FET across the output terminals


34 October 2016


Power supply output capacitors discharge slowly under light or no load conditions. This becomes problematic when performing tests at varying voltage levels, since slow discharge means slower tests. To ameliorate this, down programming circuits in power supplies rapidly decrease the output voltage and considerably lowering discharge times.


Components in Electronics


noise is minimised by eliminating ground loops, ideally providing only one connection to ground. In rack systems the DC distribution paths need to be separate from other conductive paths that carry ground currents.


Radiated pick-up is reduced by using twisted shielded conductors for the output and remote sense leads. Cable shields should only be connected to ground at one end.


Lower common-mode noise current is achieved by equalising the impedance to ground from plus and minus output terminals. It is also important to equalise


Tip 5: Connect power supplies in series or parallel for higher output Connecting two or more power supplies in series provides higher voltages. However, it is


Figure 4: Keysight 66319D dual output mobile communications DC source provides two outputs for testing both the main battery power and the battery charger circuitry


Two types of down programming


circuits are significant. In the first, an FET is placed across the output terminals. When the output voltage is higher than the programmed value, the FET activates and discharges the output capacitor. The FET can sink currents between 10 and 20 per cent of the supply’s output current rating, resulting in slight degradation of the down programming current near zero volts. Alternatively, the down programmer is placed between the power supply’s positive terminal and a negative source, which pulls the output completely down with no degradation near zero.


Tip 4: Simplify setup with autoranging power supplies With bench and rack space at a premium, being able to produce a wide range of voltage and currents with one power supply is beneficial, for example allowing DC/DC converters to be tested under several voltage and current combinations at around the same power level. A basic DC power supply


important to avoid exceeding the floating voltage rating of any of the supplies or subjecting any of the power supplies to negative voltages. Each power supply should be programmed independently to deliver an equal fraction of the total output voltage and limit current to the maximum that the load can safely handle. Connecting multiple power supplies in parallel provides higher currents, but again there are limitations. One unit must operate in constant voltage (CV) mode and the rest in constant current (CC) mode. The output load must draw enough current to keep CC unit(s) in CC mode. In modern power supplies outputs can


be grouped to create a single output with higher current and power capability.


Figure 5: The B2901A from Keysight is a precision source / measure unit featuring 1-channel with 100 fA/100 nV measurement resolution and 210 V, 3 A DC/10.5 A plus source capabilities


has a rectangular output, having a maximum voltage (Vmax) and current setting (Imax) with a single maximum power point (Pmax=Vmax × Imax). More advanced power supplies have multi- range outputs. Today’s autoranging outputs satisfy many different voltage and current combinations and eliminate the need for many power supplies.


Tip 6: Use a power supply to measure DUT supply current Accurately measuring DUT supply currents above 10A is beyond the range of typical DMMs in ammeter mode. One solution is to use an external shunt and the DMM’s voltage mode. Using the power supply itself is better. Many supplies boast an accurate measurement system, including a shunt and can be started via a single command to the power supply. With typical accuracy around ±0.5 per cent or better at full output levels, the advantages of using power sources to measure high currents is clear. Using them to measure low currents may not be so straightforward. Nevertheless, a power supply with multiple range readback caters for most requirements, offering full scale accuracy of 0.04 per cent + 15 µA at low range (100 mA) or 0.04 per cent + 160 µA at high range (3A).


www.microlease.com www.cieonline.co.uk


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117