Case Study - Yield


Since it is impossible to completely eliminate all vibration in the storage cassettes, optimum inclination is tilted back 1mm to reduce “wafer walking”. As the position of storage cassettes is often not an upright position when retrieved by the robot, it is important that levels are accurate. In this scenario, an auto leveling sensor, similar to the auto vibration sensor, was implemented to monitor level of storage cassettes against a set norm.


Leveling was also performed inside the


difficult-to-access vertical furnace to assure that when wafers are being processed at 1000c+ degrees, they are at the proper inclination. Figure 5 shows that optimally levelled stockers, levelled with an automatice levelling system tilt back 1 degree to prevent ‘wafer walking’.


Auto vibration sensor set new standards for vibration detection Whenever a wafer is moved or something within the vicinity of the wafer moves, resulting vibrations can be a potential cause of defects. Typically only a few of the common sources of wafer vibrations such as robot arm bearings or lead-screw lubrication are investigated. When comparing tools that should have identical yields, but one or more tools have abnormally high defects, investigation of the entire wafer path is key to quantify the full range of conditions to which the wafer is exposed. The diffusion team did just that using the auto vibration sensor (AVS). Once the AVS identified multiple wafer defect causes that were previously overlooked or undetected, engineers at the 200 mm fab conducted a number of corrective actions that included:  Routine maintenance such as lubrication, which was previously overlooked


 Replacement of failing or substandard parts before yield impact


 Service sub-par sub-systems such as noisy fans


 Where necessary, implement vibration damping systems such as on push-carts or tools near busy traffic areas


 Optimally level storage cassettes to reduce “wafer walking” and mishandling.


 Revise standard procedures to reduce wafer vibration where excessive vibration was identified


 Document new vibration and levelling wafer procedures for implementation into all future routine diffusion tool PMs


The AVS’ data logging capabilities also allowed the fab to establish new preventative maintenance requirements and process control standards for both the tools and engineers that are now a part of Best Know Methods in preventive maintenance of tools. As a result, all 13 tools are providing yield at acceptable levels, including the four that were at sub-par levels.


© 2011 Angel Business Communications. Permission required.


23


Figure 4a &4b


Figure 5


www.euroasiasemiconductor.com  Issue IV 2011


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40