This page contains a Flash digital edition of a book.
AUTOMATED SOLUTIONS Power Feed 10R ™


Compact Wire Drive System for Automation The Power Feed™


• Digitally controlled by the Power Wave® yielding the best performance in the industry.


power source, • Use with Lincoln power sources featuring ArcLink® , the


leading digital communications protocol for welding, making it the best choice for seamless integration with the power source and networked equipment.


• Tachometer feedback provides calibration and precise control of wire feed speed.


• Feeder brakes from maximum speed to zero in milliseconds, minimizing the chance of wire sticking in the puddle.


• Select standard or high speed gears for wide wire feed speed range.


• Split wire guides provide trouble-free feeding and offer fast, tool-less wire installation, changeover and maintenance.


• Easy-to-read gauge for accurate drive roll tension.


• Brass-to-brass connections for good connectivity between feeder and gun.


• Self loading wire feature for easy set-up. Product


Name Power Feed™ 10R


Product Number


K1780-2


Wire Feed Speed Range in/min (m/min)


50-800 (1.3-20.3) 75-1200 (2.0-30.5)


Shown:


K1780-2 Power Feed™ 10R mounted on FANUC® Robot Arm.


Wire Size Range – Solid inches (mm)


.025-3/32 (0.6-2.4) .025-1/16 (0.6-1.6)


Welding Booth


Effective Production or Training Space with Integrated Weld Fume Control


The Lincoln Electric Welding Booth is ideal for use in stationary production welding applications, vocational centers, and training facilities. It can be configured with shelving, brackets, hooks, lighting, and air/gas connections to meet the needs of the welding operator or student. Source extraction weld fume control can be easily integrated into the booth, with an extraction arm and connection to a Central System.


Welding Booth


• Rugged Steel Construction – Endures the rigors of production welding operations or training environment.


• Easy Installation – Helps to minimize start-up costs.


• Generously Sized – Plenty of room to maneuver within the work or training space. Standard booth sizes of 5 ft. x 5 ft. (1.5 x 1.5 m) and 6 ft. x 6 ft. (1.8 x 1.8 m) meet AWS guidelines for booth width and depth.


Optional Extraction Arms


• Telescopic Arm with 360° Rotatable Hood – New telescopic tube design allows maximum extension and compression. Spring-balanced mechanism provides easy movement and ensures the hood stays where it is positioned. Ideal for pipe welding; position the arm at the start of the weld and no additional adjustment is necessary. Arm length is 40-80 inches.


• Rugged Design – Made from durable dent and scratch resistant material.


• Source Capture Solution – More effective than back draft designs as a means of controlling weld fume.


Welding Booth shown with optional Welding Curtain


www.lincolnelectric.com/automated-solutions | 87


Wire Size Range – Cored inches (mm)


.035-.120 (0.9-3.0) .035-5/64 (0.9-2.0)


H x W x D inches (mm)


8.9 x 10.3 x 8.1 (226 x 261 x 206)


Processes (Power Source Controlled) • Stick • TIG • MIG • Flux-Cored • Metal-Cored • Submerged Arc


Key Options •Work Table with Adjustable Overhead Welding Bracket


•Welding Curtain • Tool Shelves with Torch Holders • Locker Box


Literature MC10-87


Net Weight lbs.(kg)


22.4 (10.2) 10R is a high performance, digitally controlled wire


feeder designed to be part of a modular, multi-process welding system. It is specifically designed to mount to a robot arm or to use in hard automation applications.


COMMUNICATIONS PROTOCOL


Key Options • K1785-25 Control Cable, Heavy Duty, 25 ft.


• K590-7 Water Connection Kit • K1733-1 Wire Straightner • K1546-1 Incoming Conduit Bushings, .025 in.-1/16 in.


• K1546-2 Incoming Conduit Bushings, 1/16 in.-3/32 in.


• More options at end of section


Literature E9.160


Processes • MIG • Pulsed • STT® • Flux-Cored • Metal-Cored


Output Input


40 VDC


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136  |  Page 137  |  Page 138  |  Page 139  |  Page 140  |  Page 141  |  Page 142  |  Page 143  |  Page 144  |  Page 145  |  Page 146  |  Page 147  |  Page 148  |  Page 149  |  Page 150  |  Page 151  |  Page 152  |  Page 153  |  Page 154  |  Page 155  |  Page 156  |  Page 157  |  Page 158  |  Page 159  |  Page 160