ENGINE DRIVES: INDUSTRIAL
Vantage 300 & 400 Compact, Multi-Process, Excellent Value
® Chopper Technology® Quiet, compact Vantage® 300 & 400 models are an ideal
choice for construction teams, pipe rig owners and rental fleet managers. Select your choice of proven 4 cylinder 1800 RPM diesel engines.
www.lincolnelectric.com/green
Processes • Stick • TIG
• MIG Output
CV DC CC
Vantage®
• Flux-Cored • Gouging
kW 12.5P
(1) 19
Package Includes • Vantage®
(2) P kW
300 Ready-Pak® 300
• Road Trailer with Duo-Hitch™ Ball/Eye Hitch Combo
:
• Fender and Light Kit • Cable Rack • Cable Connectors (qty. 2) • Electrode Cable 2/0, two 50 ft. (15.3 m) lengths
• Electrode Cable 2/0, 10 ft. (3.0 m) •Work Cable 2/0, 50 ft. (15.3 m) • 300A Electrode Holder • 300A Work Clamp
Vantage®
Package Includes • Vantage®
400 Ready-Pak® 400
• Road Trailer with Duo-Hitch™ Ball/Eye Hitch Combo
:
• Fender and Light Kit • Cable Rack • Cable Connectors (qty. 2) • Electrode Cable 3/0, two 50 ft. (15.3 m) lengths
Shown: K2410-3
Vantage® 400
Shown: K2409-3
Vantage® 300
• Electrode Cable 3/0, 10 ft. (3 m) •Work Cable 3/0, 50 ft. (15.3 m) • 400A Electrode Holder • 500A Work Clamp
Key Options • K2636-1 Medium Two-Wheel Road Trailer with Duo-Hitch™ Hitch Combo
: Ball/Eye
• Compact Case with stainless steel enclosure. • Lincoln’s®
Chopper Technology® delivers great arc starts and a smooth arc for stick, TIG or wire welding.
• Multi-Process Welding – Five process modes, including: - CC-Stick (3/16 in./4.8 mm with Vantage® 1/4 in./6.4 mm with Vantage®
400)
- Downhill Pipe (for stick) - Touch Start TIG®
DC
- CV-Wire (5/64 in./2.0 mm with Vantage® 3/32 in./2.4 mm with Vantage®
400)
- Arc Gouging – Carbon sizes up to 1/4 in. (6.4 mm) with Vantage® Vantage®
300 and 5/16 in. (8.0 mm) with the 400.
Product Name
Vantage® 300
Vantage® 300 One-Pak® Vantage® 300 Ready-Pak®
Product Rated Output
Number Current/Voltage/Duty Cycle K2409-3
300A/32V/100% 350A/28V/100%
K2452-3 K2453-3
Output Range 30-400A DC
40-300A Pipe
20-250A DC TIG 14-32V CV
3-Phase AC Power:
12.5 kW Peak , 11 kW Continuous 1-Phase AC Power:
Vantage® 400
Vantage® 400 One-Pak® Vantage® 400 Ready-Pak® Vantage®
400
Vantage® 400 One-Pak® Vantage® 400 Ready-Pak®
K2410-3 K2508-3
K2509-3 K2711-1
K2717-3 K2718-3
44 |
www.lincolnelectric.com/engine-drives
400A/36V/100% 450A/32V/100%
11.5 kW Peak , 10 kW Continuous 30-500A DC
40-300A Pipe
20-250A DC TIG 14-36V CV
3-Phase AC Power:
19 kW Peak , 17 kW Continuous 1-Phase AC Power:
12 kW Peak , 11 kW Continuous Kubota® V2403M EPA Tier 4i Perkins® 404D-22 Diesel 4 EPA Tier 4i
32.7 @ 1800 35.9 x 25.3 x 60 1,230 (559) (913 x 642 x 1524) To top of exhaust tube: 46.6 (1184)
— 35.5 @ 1800
1,245 (565) —
Type of Engine
Kubota® V1505 Diesel EPA Tier 4i
Cylinders 4
No. of HP & Speed (rpm)
H x W x D inches (mm)
Net Weight lbs.(kg)
22 @ 1800 35.9 x 25.3 x 60.0 1,035 (469) (913 x 642 x 1524) To top of exhaust tube: 44.3 (1124)
— 300, 300,
• Plenty of AC Generator Power Vantage®
300
– 12.5 kW peak (11 kW continuous) 3-phase 240V AC
– 11.5 kW peak (10 kW continuous) 1-phase 120/240 AC
Vantage® 400
– 19 kW peak (17 kW continuous) 3-phase 240V AC
– 12 kW peak (11 kW continuous) 1-phase 120/240V AC
• Low Noise – As low as 99.1 dBA Lwa sound power (74.8 dB at 23 ft./7 m) with Vantage®
400.
• K2627-2 Remote Output Control w/120V AC, 100 ft. (30.5 m), 20A capacity
• More options at end of section
Literature E6.206 (Vantage® E6.210 (Vantage®
(1)Vantage®
300) 400)
300 (2)Vantage® 400 Input D
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136 |
Page 137 |
Page 138 |
Page 139 |
Page 140 |
Page 141 |
Page 142 |
Page 143 |
Page 144 |
Page 145 |
Page 146 |
Page 147 |
Page 148 |
Page 149 |
Page 150 |
Page 151 |
Page 152 |
Page 153 |
Page 154 |
Page 155 |
Page 156 |
Page 157 |
Page 158 |
Page 159 |
Page 160