BSEE DATA CENTRES


uLe: An ambientonly cooling soluon in a mission crical environment can deliver an EER of 75 compared to an EER of just 4 for a tradional compressor based system.


uRight: Transtherm's variable speed fans operang in data centre environments can deliver annual energy reducons of around 96,000kW at a cost reducon of £9,660.


Adversing: 01622 699116 Editorial: 01354 461430


AMBIENT COOLING VS COMPRESSOR TECHNOLOGY Exploring data centre temperature control


I


As demand for data collecon, storage and exchange mulplies at an unprecedented rate, the energy consumpon of data centre infrastructure is becoming an increasing drain on energy resources. Tim Bound, Director at Transtherm Cooling Industries, explores the role of ambient cooling technologies in keeping energy costs low in data centre applicaons.


n an era where on an annual basis, data centres in the United States alone consume the entire output of 34 of the world’s largest power stations, methods of conserving and reducing the energy input of some of the globe’s most socially and economically critical buildings is more important than ever.


By 2020, the UK will be the largest single market in Europe for data centres, and analysts predict this will cost the industry up to £7bn per year in energy alone. Disclosure of data centre energy and carbon performance metrics is now driving change in a sector where the potential energy savings could comfortably sit in the hundreds-of-millions. There are a number of ways to deliver power savings in data centres, from optimising renewable energy sources, to updating the physical infrastructure of the building, investing in modern server technology with lower heat emissions, or carefully specifying the right cooling equipment.


Why is ambient cooling technology increasing in popularity?


Historically, data centres have been cooled using compressor or refrigerated technology, often with an adiabatic cooler installed to dissipate the heat generated by the compressor. The performance of this conventional chilling technology has serviced the mission critical data centre sector well thus far, but change is definitely afoot. There is a distinct shift in popularity from traditional compressor based chilling methods to far more energy efficient ambient cooling technologies, with a particular focus on adiabatic solutions due to its retrofitting capabilities compared to other ambient systems such as direct evaporative or heat exchanger technology. Why? The two main drivers for change are a surge in investment in the construction of new or extended data centres, plus a significant improvement in the operating parameters of server technology.


The global data centre construction market is estimated to grow from $14.59bn in 2014 to $22.73bn by 2019, at a Compound Annual Growth Rate (CAGR) of 9.3%. This thriving market growth is down to many companies transforming traditional facilities into mega data centres and others planning to build new ‘monster sites’ in the coming years. With modernisation, comes state-of-the-art server technology which is capable of withstanding higher temperatures whilst maintaining optimised performance and reliability. The modernisation of legacy data centre infrastructure, the increased construction of new ultra-modern sites and the widespread adoption of more temperature resilient servers has driven a desire for compressorless cooling, choosing the energy efficient benefits of ambient cooling technologies instead.


Why is this happening now?


Historically, ambient cooling equipment has been unable to cool data centres to within the right temperature range,


38 BUILDING SERVICES & ENVIRONMENTAL ENGINEER SEPTEMBER 2018


which created an industry reliant on refrigerated or compressor led solutions. Now, thanks to more adaptive build methods and the marginal, but vital, increase in server temperature resilience, the temperature parameters of data centres has risen to a range which ambient cooling technology can comfortably achieve.


In other words, instead of cooling the compressor, adiabatic equipment is now directly cooling the data centre equipment itself. This is reducing CAPEX expenditure by eradicating an entire chiller from many new build specifications.


Why is this a more energy ecient soluon?


Adiabatic and other ambient cooling equipment achieves lower Energy Efficiency Ratios (EER) than compressor based chillers. Take the example of a typical compressor chiller which will consume 1kW of energy for every 3-4kW of cooling delivered.


Compare this to an equivalent sized adiabatic solution, which for the same 1kW of energy consumed, will deliver up to 75kW of cooling.


In terms of EER, this difference translates as an approximate EER of 4 (4kWth/1kWe) for a conventional compressor solution, and an impressive EER of around 75 (75kWh/1kWe) for the equivalent ambient solution. This of course, translates to substantial energy and cost savings for energy-hungry mission critical environments.


Can legacy data centres sll benefit from ambient cooling?


Older data centres which house older style servers will still rely on compressor or refrigeration chillers to dissipate enough heat from the data centre, and maintain an internal building environment which meets the operational temperature thresholds of dated server technology.


That said, given that most leading ambient coolers are installed externally, retrofitting additional cooling technology to supplement an existing compressor solution is a highly viable option for many older data centres looking to maximise geographical assets and weather patterns to deliver free cooling during certain seasons.


If an older data centre retains its legacy infrastructure but is refitted with state-of-the art servers which can operate at higher temperatures, adiabatic cooling equipment can be retrofitted to the same inlets as older equipment. As the data centre industry evolves and grows at a rapid pace, energy conservation focused industry leaders like Facebook have already maximised ambient and free cooling technologies within their data centres. As we move towards a future even more reliant on the storage and exchange of data, the rest of the industry is expected to follow suit.


www.transtherm.co.uK VISIT OUR WEBSITE: www.bsee.co.uk


There are a number of ways to deliver power savings in data centres, from opmising renewable energy sources, to updang the physical infrastructure of the building, invesng in modern server technology with lower heat emissions, or carefully


specifying the right cooling equipment.





Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58