Non contact measurement & inspection
consumption and cut costs wherever possible. In this new (increasingly costly) reality, acoustic imaging is offering manufacturers a crucial lifeline; it is helping energy-intensive industries to keep the lights on by driving down operating costs and slashing maintenance expenses. You have heard of ‘lossless sound’. Well, acoustic imaging takes that quite literally.
B
DETECTING PREVIOUSLY UNDISCOVERED AIR LEAKS CAN PLUG A COSTLY PROBLEM For the UK and much of the EU, the cost of energy has almost doubled from this time in 2021, with prices now at 34.0p/kWh (versus just 18.9p/kWh in 2021). That is 179 per cent higher. In fact, gas prices have increased in 23 of the 24 EU Member States for which data are available, with the biggest jumps after the UK being seen in Estonia (+154 per cent), Lithuania (+110 per cent) and Bulgaria (+108 per cent). This begs the question ‘how can energy-intensive industries survive in this climate?’ With large-scale industrial processes driven largely by compressors and vacuum pumps to operate machines and transport assets, that is a critical question. The answer is of course to look at your outgoings and real, tangible ways to cut expenditure on the factory floor. One way that is rapidly picking up traction among manufacturers across the breadth of the EU is acoustic imaging. No piece of equipment is immune to the issue of machine failures and wear - however high-tech they are. Machines that are not operating optimally are costing you money in very real terms. This is where acoustic imaging comes in; on the frontline of condition monitoring, it promises to yield savings by picking up air leaks in real time. While isolated incidents may seem minimal, the costs of wasted energy can quickly snowball from a minor inconvenience to an acute concern. Consider that with the average compressor system, approximately 80 per cent of energy is lost through heat dissipation, meaning only 20 per cent makes the transition into a usable output on the factory floor. From this, up to a third of this usable energy is lost to leaks. Energy that you are paying more and more to use.
WHY ARE AIR LEAKS SO EXPENSIVE? Let us put a measurable scale on a problem that can vary substantially by application. To do this, operators must first explore exactly how much a leak can impact production costs. Take, for example, a compressed air leak from a small hole of just 1.5 millimetres on a network of compressed air at seven bars of pressure. Two years ago, with a price of €0.07 per kilowatt hour, that alone would have cost a company roughly €1,500 (£1,300) if you assume an operating time of 6,000 hours per year. Of course, now the energy situation is worsening, which means that costs may be
38
usinesses are struggling to cope with compounding costs and rising energy bills - that much is clear. In the face of surging costs and in the absence of certainty, businesses across the globe are looking to reduce
MANUFACTURERS ARE DRIVING DOWN RISING ENERGY BILLS WITH ACOUSTIC IMAGING
three, four, even five times higher in some cases - which could be a cost of up to £7,500 a year for failing to identify a single small hole in a vital production component. When you consider the scale of industrial manufacturing and the scope for leaks to crop up unnoticed, it is staggering that such a comparatively small hole can compound into such a large problem.
DRIVING DOWN ENERGY BILLS Newer acoustic imaging camera models such as the FLIR Si124 use a number of high-spec audible and ultrasound microphones to detect air leaks as they appear and boast an optimal bandwidth range of 2 - 65 kHz. This range yields unmatched detection accuracy and identification down to even the smallest breach. The technology also gives handlers the ability to
identify, photograph or video the location of an air leak up to ten times faster - meaning minimal downtime for the facility and a prompt repair or replacement of the defective component. In addition to this, it also detects partial discharge, floating discharge and corona - helping to curb potentially life-threatening events, as well as general maintenance issues.
Operators benefit from the much quicker identification of problem parts and even have the capability to see the detected leak(s) as they appear. This is because the sound is superimposed by functional AIs to render a visual depiction of where the leak is - as well as gauging its severity, including recommended actions to resolve. In the case of the FLIR Si124, projective algorithms even estimate how much the leak will cost by evaluating the air lost in real-time, calculating the spend per kWh and displaying an expecting saving per year (or on a specified timeframe) - ensuring that inspectors have clear evidence needed to solve problems and justify any incurred repair costs across the production line. If you are a manufacturer struggling with the rising cost of energy, explore the new si124 range now to radically improve inspections in your facility.
Teledyne FLIR
www.teledyneflir.com March 2023 Instrumentation Monthly
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82