Here, The Preparation Group looks at how to pick the right vacuum for a situation, whether you’re after dust, liquids of hazardous materials.


When selecting a vacuum, it’s important to look for robust, durable, steel models that feature high filtration standards and high airflow. The chosen dust extraction must also match the operation that it is to be used for.


To safely contain dust in dust- sensitive environments or in dealing with hazardous airborne particles, The Preparation Group offers three vacuum models and a pre-separator that feature Longopac Safe Bagging Systems, eliminating the need to empty a ‘bin’ as found on conventional dust extraction units.


Instead, debris is collected into a continuous feeding bag which is then twisted and sealed by the operator into manageable bags for disposal. There is a two-motor 202DSLP vacuum, three-motor M450LP vacuum as well as a 202DS Atex model, which is Category Zone 22 rated for use in food, pharmaceutical and petrochemical environments.


The Longopac Pre-separator connects to another industrial vacuum to yield even greater suction and dust containment properties. This unit is particularly popular with specialist asbestos contractors to avoid handling of material during the removal processes. With a Pre- separator, the system can be used for long range projects, i.e. at high level multi-storey buildings, with the preparation equipment and Pre- separator on the working floor and the industrial vacuum at ground level, up to 150 metres away. This eradicates the handling of any contaminated materials and, if planned and executed correctly, ensures that no hazardous materials will enter the atmosphere.


SELECTING A FILTER When removing airborne particles, it is important to select the correct vacuum filter. There are three main types; L, M and H (low, medium and high). Medium Class Filters are general purpose suitable for standard operations. A vacuum must be fitted


42 | VACUUMS & SWEEPERS


CASE STUDY:


with an L or M type filter in order to correctly function, but can also be fitted with an additional H grade filter for collecting very fine, asbestos- containing particle dust.


A vacuum fitted with an H filter is by definition an H-type Vacuum and should have an ‘H’ sticker on it. To double check that one is fitted, take the head off the vacuum to confirm that there are two filters inside, one will be an H filter.


DRY/WET VS WET/DRY When there is a need to vacuum both dry and wet materials, there are dual purpose dry/wet industrial models on the market such as the M450 that effectively remove both, without the need to change the filter system. The dry/wet vacuum’s filter is specially designed yet is equally effective at dealing with slurry. Wet/dry vacuums are primarily designed to deal with liquids but can be used on dust, so they don’t share the same high levels of dust particle containment and can clog.


www.thepreparationgroup.com


ASBESTOS The Preparation Group’s contracting division, PPC, were contracted to remove floor adhesive containing traces of asbestos from a block of council flats in Huddersfield, which were due for demolition.


The building comprised of 10 floors and equipment had to be manually lifted to each level as the lift had been disabled. The company’s 250 Grinder fitted with a PCD (Polycrystalline Diamond) Plate was used, with 9” hand grinders fitted with PCD discs employed to complete the edges. Debris and fine dust particles were collected safely by an M450LP Longopac industrial vacuum fitted with an ‘H’ grade filter, and the contaminated material was contained in special asbestos bags.


The total area of 1,413m2 took six


days to complete. The contaminated material represented a small percentage of the overall structure so by disposing of this element separately, it meant that the whole building was not classed as contaminated waste, thus reducing environmental impact and costs.


twitter.com/TomoCleaning


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102