CIVIL AND ENVIRONMENT CONSULTANTS ADD TIGER LT PID TO GROWING PORTFOLIO OF ION SCIENCE HANDHELD VOC MONITORS


Latest instrument chosen for competitive price point, streamlined yet durable design and anti-contamination and humidity resistance


Following an increase in demand for its services, Massachusetts-based Civil & Environment Consultants Inc. (CEC) has added a streamlined TigerLT VOC (volatile organic compound) monitor to its growing portfolio of Ion Science handheld PIDs (photoionisation detectors). This latest instrument was chosen for its durability in the fi eld, extremely competitive price point and anti- contamination and humidity resistant design.


CEC Inc. provides comprehensive market-oriented consulting services that advance client strategic business objectives. The company is recognised for delivering innovative design solutions and integrated expertise in civil engineering, ecological sciences, environmental engineering and sciences, waste management and water resources.


Kyle Fortin, Project Scientist at CEC Inc. comments: “We implement projects that range from overseeing hazardous / non- hazardous contamination clean-ups to designing and maintaining landfi lls. Our equipment rental company, US Environmental Rental Corporation, has typically recommended Ion Science handheld Tiger PIDs in the past for headspace screening of total organic vapours (TOVs) in soil, ambient air screening during chemical clean-ups and VOCs in landfi ll soil gas probes.


“US Environmental Rental Corporation is extremely trustworthy and has helped our business signifi cantly over the years. As a result, we are happy to go with their suggestion that a specifi c instrument is superior to comparable VOC monitors on the market.”


Offering worldwide intrinsically safe (IS) certifi cation for use in potentially explosive atmospheres, the recently launched TigerLT is a streamlined, lower cost version of Ion Science’s well-proven Tiger instrument.


Kyle continues: “Our offi ce has doubled in size during the past three months so we had an urgent need for an additional PID. The TigerLTwas a great choice because of its competitive price point and proven reliability of the Ion Science instruments we have experienced in the past.”


The TigerLT incorporates Ion Science’s market-leading MiniPID 2 technology with advanced patented fence electrode system. The three-electrode format ensures increased resistance to humidity and contamination for ultimate reliability and accuracy in the fi eld, as well as considerably reduced drift issues and extended run time.


“We generally use the TigerLT for fi eld screening of VOCs in dusty or humid conditions therefore the anti-contamination and humidity design is crucial for our line of work in the environmental fi eld,” comments Kyle. “The durability and reliability of the TigerLT is exceptional for outdoor use especially in New England where temperature and weather can experience extremes.”


With a detection range of 0 to 5,000 parts per million (ppm) with a 0.1 parts per million (ppm) minimum sensitivity, TigerLT offers a response time of just two seconds and is equally quick to clear down.


Simple to operate and service, TigerLT allows easy access to the lamp and sensor whilst the batteries


can be safely replaced in the fi eld. It also meets required ATEX, IECEx, UL and CSA standards.


“We are using the TigerLT up to three times per week with data recorded in our fi eld books. The calibration is easy and keeps the accuracy and reproducibility within an acceptable range,” adds Kyle.


The TigerLT six pin MiniPID detector cell with anti- contamination design dramatically extends run time in the fi eld. Low cost fi lters and lamps can be easily changed in minutes, minimising downtime.


TigerLT


The instrument features long life rechargeable Li-ion batteries which give up to 24 hour usage. Fast battery charging allows it to be fully charged in 6.5 hours, while up to eight hours of use can be achieved from 1.5 hours of charging time. Performing basic functions does not require complicated set up procedures using a PC.


TigerLT features a protective, removable boot for harsh environments and large, clear back-lit display allows for easy viewing in any light condition. It is IP 65 rated against water ingress. An integrated torch is designed for directing the instrument’s probe into dimly lit areas. Other features include a loud 95 dB audible alarm and multiple language support.


Kyle continues: “The distributor recently gave a presentation on the Ion Science product range at a seminar my young professionals committee helped to organise. It was very useful for other companies to see the reliability and durability of the Tiger instruments.


“We have nothing but good things to say about the Ion Science Tiger series of handheld PIDs and the distributor is always very helpful when questions arise,” he concludes.


For product information contact: Emily Lane, Ion Science, The Way, Fowlmere, SG8 7UJ UK tel: + 44 (0) 1763 208503 • email:marketing@ionscience.comwww.ionscience.com


IET May / June 2017 www.envirotech-online.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56