ANALYTICAL INSTRUMENTATION
Flash and Fire Point of Asphalt by Cleveland Open Cup (COC) Tester (ASTM D8254-19)
Published by ASTM in June 2019, ASTM D8254 describes the determination of flash and fire point of skin-forming and non- skin-forming asphalts by a manual or automated Cleveland open cup apparatus. It is applicable to products with flash points above 79 oC and below 400 oC. Determination of the flash point of asphalt samples that form a skin during the course of the test presents unique challenges. ASTM D92 suggests skimming or removal of the skin prior to passing the test flame over the test sample surface. Using a technique for prevention of skin-formation which was first introduced by ASTM under an Appendix of D92 produces flash point results which are lower than those obtained by skimming or removal of the skin. This technique, embodied in ASTM Method D8254, provides added safety and convenience particularly for those performing the D92 test on asphalt samples manually. Under D8254, asphalt sample is poured into a COC flash cup that is previously prepared for the test with a single-holed qualitative filter paper and restraining ring in its base. The test procedure is generally similar to D92.
Pensky-Martens Closed-Cup Test (ASTM D93)
In 1921, ASTM also added the Pensky-Martens Closed-Cup Test, which was based on an apparatus designed by Adolf Martens and Berthold Pensky in Germany. The apparatus consists of a test cup usually made of brass (55.75-56 mm depth, 1 mm side thickness, 2.29-2.54 mm base thickness), a brass cover and shutter, a flame- type or electric resistance-type heater, an air bath, and a stirrer which is mounted in the center of the cover. There are three different Procedures (A, B, & C) that can be used depending on the type of specimen that is tested. Procedure C is specifically for biodiesel and only describes an automatic tester. Each procedure has its own stirring and heating rate and as opposed to previous methods, all procedures start stirring while the test specimen is heating and then stop stirring whenever testing for the flash point. This method requires around 75 mL of sample [2,6]. An automatic version of the tester is shown in Figure 2.
Tag Open-Cup Test (ASTM D1310)
The Tag Open-Cup Test was adopted by ASTM Committee D01 in 1952. This method is open-cup, unlike D56, but also differs from that method by having a test cup made of clear, annealed glass. The test cup here has a depth of approximately 47.6 mm the heating rate generally stays at about 1°C/min with no stirring. The sample in the cup is about 90 mL [2,7].
Small-Scale Closed-Cup Test (ASTM D3828)
In 1979, ASTM Committee D02 approved the use of a “small- scale” tester which allowed for the use of a smaller sample size. The sample size here can be either 2 or 4 mL and the test cup has a depth of only 9.7-10 mm and a diameter between 49.4 and 49.7 mm. The test cup is made of either aluminum alloy or another metal with suitable conductivity. These dimensions and the procedure in this method allow for thermal equilibrium testing of flash point, where the vapor and liquid are at the same temperature during ignition. This method also has a procedure for determining flash/no-flash at a specified test temperature and a separate procedure for determining flash point more traditionally [2,8].
Continuously Closed-Cup Test (ASTM D6450/D7094)
The method using a continuously closed-cup apparatus was approved by ASTM in 1999. The apparatus contains a solid brass lid and a sample cup made of nickel-plated aluminum or another metal with similar conductivity. The cup has a volume of 4 mL and accommodates only 1 mL of sample for the test. Because of the sample size, it has been much safer to conduct compared with the sample sizes in excess of 50 mL in previously approved methods. The ignition source is a high voltage electric arc and a pressure transducer is used to determine the flash point. The flash point is recorded when there is a sudden increase in pressure
inside the cup of at least 20 kPa above barometric pressure. There is also an air supply which introduces about 1.5 mL of air into the test cup after each ignition. A method known as the modified continuously closed-cup test (ASTM D7094) was introduced in 2004. This method uses the same apparatus but it features a 7 mL sample cup with a sample size of 2 mL and also uses a different heating rate [2,9].
Why are there many different flash point tests?
The section above is not meant to be an exhaustive list of all the different methods in use. There are a few more that are widely used, and more information on these can be found in The Practice of Flash Point Determination: A Laboratory Resource published by ASTM International [2]. However, from the sections above, it is clear that the different methods that have been developed all have detailed parameters that are unique to each, such as test cup material, test cup dimensions, heating rate, stirring rate, sample size, and so on. This is one of the reasons why flash point testing is not a “one size fits all” endeavor. There are test specimens which would benefit more from a certain set of operating conditions than another. For example, a very viscous liquid might be better tested in a method with a faster stirring rate. This is why some of the methods outline in their scope that they are most useful for liquids within a specific viscosity range.
One of the most important considerations in flash point testing is using an open-cup vs. closed-cup apparatus. The reason both open-cup and closed-cup tests exist is to attempt to recreate certain conditions that may be encountered in the real world. Closed-cup testing is meant to simulate what would happen if an ignition source were introduced accidentally into a sealed container or other type of closed system containing the test specimen. Open-cup testing is meant to simulate the event of either a spill of the test specimen in an open area or to simulate storage/transport conditions in an open system. Regarding the methods of the tests, there is not a significant difference in procedures when looking at open vs. closed-cup testing and there are no special considerations to be made when using one method or the other. What is important to understand is that open-cup tests will always give a higher flash point than closed-cup tests for a given substance. This is because in an open-cup test, a significant amount of flammable vapor that emerges from the test specimen is able to leave the immediate area above the liquid surface. At the time of ignition, there is a lower concentration of flammable vapor in the test cup then there would be in a closed cup. In closed-cup testing, the vapor is not given much chance to escape and there will always be a higher concentration of flammable vapor in the test cup, which means that it does not require as much heating to reach a temperature where the vapor will ignite. This phenomenon also results in closed-cup tests usually having better precision than open-cup tests, which is why closed-cup tests are usually recommended in specifications for products [10].
Another consideration in flash point testing that has developed over time is the option of using manual vs. automatic testers. Back when these methods were first developed and approved, all of the testers were manual, which meant the operator had to execute every step of the procedure by hand and also needed to determine a flash by eyesight. Most of the methods now have automated testers that have been designed according to the materials and dimensions outlined for the manual apparatus. This development came to fruition largely due to safety concerns in addition to the operator’s convenience. With automated testers, the operator no longer needs to apply the ignition source and is free to do other tests in the lab during the brief time that the test is taking place in the automated tester. Most of the methods specifically state that an automated tester is acceptable to use as long as it is able to perform all of the detailed and specific steps from the manual procedure and There have also been numerous studies and tests which have shown that there is no statistically significant difference between the results obtained by manual testers and their automated counterparts [2]. These are the reasons why automated testers have become very popular over the years. However, in cases of dispute, it is typically preferred to carry out a test with a manual apparatus so that the operator can confirm that every step took place correctly and that an appropriate flash was observed at a certain temperature [10].
7
Figure 2. The latest automatic Pensky-Martens Closed Cup Tester (Koehler Instrument Company).
A note should also be made about the question of whether results from one method can be directly compared or correlated with results from another method, or if methods can just be substituted between each other. Due to the fact that the various apparatus designs and procedures in each method are very specific and they are each unique, it is not recommended that two different methods be compared directly. Most of the methods under the jurisdiction of ASTM Committee D02 begin with the following message which addresses the issue:
“Flash point values are a function of the apparatus design, the condition of the apparatus used, and the operational procedure carried out. Flash point can therefore only be defined in terms of a standard test method, and no general valid correlation can be guaranteed between results obtained by different test methods, or with test apparatus different from that specified.” [4-6]
This is the reason why whenever a value for flash point is listed on a specification or datasheet, it should always be listed along with the method that was used to obtain the value.
How do we know which method to use?
When we are trying to decide which method to use for a specific product, it is very important to know how that product is classified and to know as many physical characteristics about that product as possible. Each method will usually outline which different types of test specimen it can accommodate and also it may give information about testing within a specific range of flash point or within a specific range of viscosity. These guidelines which are on the method itself can be used to help make a choice on which method to use. While the methods themselves can be referred to, it is usually known exactly what type of product is being tested. In this case, the operator should refer first to the specification for that product (usually published by ASTM International). The specification will list the value of the minimum flash point that the product can have and will also list the method that should be used to get that value. If a product with a certain specification is being tested, then it is not recommended to replace the method outlined in the specification with another method, unless there are very special circumstances or there is approval for this to happen. Not all specifications contain a minimum required flash point and there are also some specifications where certain grades have a minimum flash point and some other grades do not. These are usually the products that have the lowest flash points and are normally quite volatile, such as liquefied petroleum gas (LPG) and automotive spark ignition fuels [2].
Here we will go over some of the major classes of products and discuss which methods have been approved for them. The methods that have been approved for diesel fuels (specified in ASTM D975) are ASTM D93, D56, and D3828. The reference method is D93 and the other two have been approved as alternate methods. ASTM D3941, which is a closed-cup equilibrium method, may be acceptable in certain cases to better understand the flammability characteristics under controlled lab conditions. For normal fuel oils (specified in ASTM D396), ASTM D93 is the reference method for all grades and ASTM D3828 has been approved as an alternate for all grades. ASTM D7094 can also be used for all grades. ASTM D56 can be used as an alternate
ANNUAL BUYERS’ GUIDE 2022
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80