EXTERNAL ENVELOPE


The practicalities of providing an outdoor living space


Balconies can enhance residential developments and provide the amenity of outdoor living space for residents. Lee Barber of Balcony Life explains how bolt-on cantilevered steel systems can avoid structural issues and problems with thermal bridging


olt-on cantilevered steel balconies are an architectural feature that is becoming increasingly popular both in new build apartments and the housing market more widely, as they provide visual interest and signify a quality development to prospective buyers. Balconies offer homeowners an outdoor living space and are seen as a desirable addition to a dwelling. From a structural perspective the difficulty with balconies (and for that matter any architectural feature located outside of the building’s insulation envelope), is how to support the balcony while avoiding a thermal bridge between the internal building structure and the balcony steel frame in order to comply with the Building Regulations Approved Documents and meeting the requirements of the thermal modelling calculations for limiting thermal bridging. Thermal bridging occurs when conductive materials, such as steel or concrete, provide a path for heat energy to flow across a building’s thermally insulated layer, resulting in heat loss and the potential for condensation to form. One solution to this problem is to design the balcony with support posts on concrete foundations and bolt the balcony steel frame to the outer masonry leaf. This approach is likely to avoid the thermal bridging issue and is generally the only viable option on existing properties. However the dwelling outer leaf may not be load-bearing, for instance lightweight cladding materials, and support posts are widely considered to be detrimental to the appearance of new build dwellings. Fortunately for architects the construction industry has addressed these issues with companies specialising in bolt-on cantilever steel balconies ffering complete balcony packages which are practical and excellent value for money, and comprise the balcony and


B ADF JUNE 2019


structural thermally broken building connection systems. Typically these balcony packages are installed as a first fix and then a second fix item. The first fix installation commences with the building connection plate which, depending upon the floor construction, is either bolted to solid timber joists or a concrete floor slab. The essential structural thermal break component is bolted to the connection plate and is ideally located within the building insulation layer, thereby minimising or eliminating the thermal bridge. A steel stub is bolted to the structural thermal break, which is designed to project beyond the face of the external envelope and position the balcony steel frame at the correct floor level. After the first fix is installed, the contractor continues with the wall construction so that when completed the stub faceplates are left exposed for the second fix balconies. The installation of the balconies usually takes place towards the end of the build programme on site and is simply a matter of offering the balcony steel frame up to the stub face plates with lifting equipment and bolting them on, after which the balcony glass balustrade or metal railing balustrade and balcony decking are installed. Balcony rainwater drainage is frequently raised as a concern, but here again companies specialising in bolt-on cantilever steel balconies provide a solution with a controlled rainwater drainage system which eliminates the need for unsightly external rainwater pipes and avoid taking rainwater pipes into the building, which could have the potential to leak and cause damage to the building fabric and interior. The principle of controlled rainwater drainage is very simple with rainwater being allowed to flow into the balcony, and prevented from draining through the balcony with a soffit panel to the underside of the balcony.


WWW.ARCHITECTSDATAFILE.CO.UK


55


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92