DATA CENTRES


UPS Triple Mode communication ensures high availability


Mike Elms


For data centres, power protection systems must be available every second of every day and therefore maximizing system availability must be the overriding objective of any installation. Availability is best described as the percentage of system uptime achieved in a year. To achieve maximum availability, all single points of failure within the UPS need to be removed. Over the years, many improvements have been made in relation to UPS technology & configurations to increase availability, reports Mike Elms, Sales & Marketing Director of CENTIEL Ltd.


A


vailability requires duplication and redundancy which naturally intro- duces inefficiencies, thereby increasing energy requirements.


For example: thirty years ago, the only way


to achieve redundancy was to install a number of standalone UPS modules in a parallel topology. These stand-alone systems could be pretty


big, for example: 60KVA UPS weighed around 600kg and was the size of a double wardrobe! In addition to the UPS modules were the associated battery systems. The introduction of transformer-less


technology in the early 1990s, by Filippo Marbach, dramatically increased efficiency, decreased size, weight and reduced costs. The true modular UPS concepts, introduced after the year 2000, resulted in even further improvements The 4th Generation true modular UPS


systems now available, provide a significant improvement over previous system designs. This is because each module contains all the power elements of a UPS – rectifier, inverter, static switch, display - and critically - all control and monitoring circuitry. This places it above other current designs


The Centiel Range.


that have a separate, single static switch assembly and separate control or intelligence modules as there is no single point of failure. Availabi lity for our CumulusPower™ UPS


which incorporates this Distributed Active Redundant Architecture (DARA) system is now ‘nine-nines’ or 99.9999999%. Hot-swap capability lowers the Mean Time to Repair (MTTR) to only around three minutes. Scalability and flexibility are also important


when installing a system to ensure the continual ‘right sizing’ of the UPS. A system which is too small will be


overloaded, compromising reliability and availability. One which is too large will waste energy, be inefficient and costly to run. CumulusPower™ offers a flat efficiency curve across the whole load range, particularly at lower loads which are inherent in parallel redundant UPS configurations. CumulusPower™ offers 97% efficiency even at these low loads. Duplication and redundancy of UPS


components must also apply to the communication cables between UPS modules. The most simple communications bus is a single cable. If this breaks or becomes


“The 4th Generation


true modular UPS systems now


available, provide a significant


improvement over previous system


designs. This is because


each module contains all the power


elements of a UPS.”


- Mike Elms, CENTIEL Ltd


24 JULY - AUGUST 2018 UK Power NewS


disconnected, the entire system could be compromised. For this reason, the ring circuit was


introduced to the majority of modern UPS systems. If the circuit breaks the signals can simply communicate the other way around the ring. The recent introduction of the Triple Mode communications bus increases system availability even further. Like its name suggests, there are three


paths of communication between UPS modules and frames made up of three separate ring circuits. Three brains communicate with three other brains – it’s the belt, braces and buttons approach. We liken Triple Mode to the comparison of


a tightrope walker. If a tightrope breaks, the consequences will be dramatic and far- reaching. In the same way, a single communications bus is far more precarious than a Triple Mode ring connection which is more like a bridge with multiple supports. Here the single points of failure are


completely removed. Even if one or several bridge struts fail, the others will support the load. It does beg the question: how would you prefer to cross the chasm? UPS technology has seen huge develop-


ments over the years. With reductions in footprint and increases in efficiency and availability, the Total Cost of Ownership is now significantly lower. The most modern UPS have become


about as close to perfect as possible, keeping in mind there will always be some losses due to the very nature of switching. The incorporation of Triple Mode communications buses further mitigates the risk and moves us fur ther towards power protection perfection. The team at CENTIEL has been at the


forefront of UPS development over the several decades. Our goal is clear: to achieve the ultimate availability of power for our client base. Our leading-edge technology, backed-up with our comprehensive maintenance contracts ensure our clients’ power has the very best protection at all times, now and in the future. For further information about CENTEIL please see: www.centiel.co.uk


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44