The Aprilaire zoning products solve the problem of inconsistent, uncomfort- able temperatures by placing a thermostat in each area to be controlled. Heating and cooling is then directed by the selective opening and closing of dampers, located in the systems ductwork, to obtain even temperatures on different levels and areas of the home. Conditioned air is delivered where you want it, when you want it, and at the temperature you want it. Zoning systems are compatible with programmable and non-programmable 24 volt thermostats.
QUICK SELECTION PROCESS:
1. SELECT THE ZONE CONTROL PANEL a. Determine the number of dampers to be used. b. Determine the type of system (i.e. Conventional or HP). c. Determine the number of stages (i.e. Single or Multi).
2. SELECT THE DAMPERS REQUIRED a. Determine the type and size.
3. SELECT THE BYPASS DAMPER SIZE REQUIRED 4. SELECT THE THERMOSTAT TO BE USED
1 2 3
Model 6202 Model 6203 Model 6303 Model 6404 Model 6504
ZONE CONTROL PANEL SELECTION: Conventional Heat / Cool
2 •
•
• •
Single-Stage 3
4 •
• •
• •
•
• •
• •
• •
•
• • •
• • •
• •
•
• •
• •
• •
• 4-12 2
Multi-Stage 3
4 4-12 2
Single-Stage 3
4
Heat Pump 4-12 2
Multi-Stage 3
4 4-12
ZONE CONTROL PANELS 6200 SERIES ZONE CONTROL PANELS
The 6200 series zone control panels are designed to be used with single stage conven- tional heating and cooling systems. Panels are equipped with LED operation indicators.
Includes Plenum Temperature Sensor. CAT. NO. MFG. NO. NUMBER OF ZONES EACH 5H460A 6202 5H460B 6203