search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
CHILLER SPOTLIGHT Chiller upgrade for


extraordinary London venue Carrier Commercial HVAC recently completed a chiller replacement project at one of London’s most extraordinary venues, the ArcelorMittal Orbit in Queen Elizabeth Olympic Park, Stratford.


D


esigned by sculptor Sir Anish Kapoor and engineer Cecil Balmond, the ArcelorMittal Orbit is one of the most striking and enduring visual legacies of the London 2012 Olympic and Paralympic Games. It is the UK’s tallest sculpture and at the summit, off ers a 360-degree view of London. The project involved replacing an ineffi cient chiller that had come to the end of its life with a Carrier AquaSnap 30RB 160R air-cooled liquid chiller, with scroll compressor, plus an added de-superheater heat recovery option. The 30RB chiller also has refrigerant leak detector, compressor soft starter, super enviro- shield anti-corrosion protection, and water exchanger frost protection.


Carrier was commissioned by ParkServe, on behalf of London Legacy Development Corporation (LLDC), to undertake the project, and enlisted the support of local contractor L&B Technical Services Ltd to complete the challenging installation. Given the height and location of the ArcelorMittal Orbit’s roof plant area, at the top of the 114-metre-tall structure, securing a crane permit was costly and complicated. However, the only access to the roof plant room was through a 1m x 1m hatch. To overcome this challenge, Carrier’s service technicians recommended and performed a strip down and rebuild of the 30RB unit. The chiller was dismantled off -site, packed into a ‘kit-of-parts’, and


The chiller almost fully assembled 34 November 2024 • www.acr-news.com


then transported to the roof plant area through the narrow access hatch. The unit was then meticulously reassembled on-site, eliminating the need for a crane and signifi cantly reducing the overall cost. This method was not only cost-eff ective but also ensured that the chiller was installed without compromising the warranty. “This was a great project to work on. Squeezing a chiller through a 1m x 1m hatch isn’t something we do all that often,” said Rob Moff at, contracts manager, L&B Technical Services. “The crane option was quoted for, but the cost for a Carrier strip and rebuild service was a fraction of the price. We are proud of our partnership with Carrier and this project exemplifi es our abilities to deliver complex and innovative HVAC solutions even under challenging circumstances.” “The project presented several logistical challenges, particularly with the limited access to the roof plant area, but Carrier’s innovative strip down and rebuild was the best approach,” said Hannah Barclay, head of contract management, London Legacy Development Corporation. “This new modern chiller not only helps meet the current climate control needs inside the ArcelorMittal Orbit but the addition of a heat recovery de-superheater provides a sustainable solution for years to come.”


Download the ACR News app today


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44