Oscilloscope plays key part in pre-compliance drives testing


The Yokogawa DLM4000 eight-channel mixed-signal oscilloscope is playing a key part in pre-compliance tests on high- power inverter drives produced by PCS (Power Convertor Solutions GmbH) in Berlin, Germany


The PCS inverters are modular and can be simply scaled in terms of size and performance to the particular application. Each module incorporates several IGBTs connected in parallel to achieve the required high currents. Modules can be combined in compact configurations: something that is particularly important for wind turbines, as there is generally little space available and the inverters may have to be installed in the nacelle. Before a new inverter can go into production,


T


he company, part of the Knorr-Bremse Group, develops and manufactures modular inverter


systems for power ratings from 5kW to 7MW. The smaller converter systems are mainly used in rail vehicles for on-board power supplies, whereas the larger systems are used in test benches and to compensate for the voltage and frequency variations encountered in power supply distribution systems and wind turbine generators. In test-bench applications, the inverters are capable of controlling electric motors used for driving or braking when testing engines and other components of the powertrains of motor vehicles. For example, it is possible to use a PCS-powered drive to replicate torque surges, which typically occur with every ignition in a combustion engine. Therefore it is the perfect setup for tests without requiring the original engine. Another field of application is partial discharge measurement or the determination of various physical and electrical parameters of very large transformers. PCS inverters are also used in wind turbines to


minimise the problems caused by short voltage dips on the mains and load shedding when the wind turbine shuts down. This is a problem on large wind farms because the network is suddenly left without several megawatts of generation capacity. These problems can be avoided by using a modern power converter in parallel, and PCS inverters are now being used to upgrade earlier wind turbine systems accordingly. A typical PCS system uses an AC mains voltage input and a DC link voltage (up to 1,000V), which in turn is converted to an AC voltage output. The advantage of this approach is that the frequency and amplitude of the output voltage correspond exactly to the requirements of the particular application. This allows optimum motor control with high dynamics. The principle can also be reversed so that, for example, the fluctuating output voltage of a generator can feed directly into the grid.


numerous measurements and tests are required. In the development department at PCS, a Yokogawa DLM4000 mixed signal oscilloscope is used to carry out these tests. This instrument was selected because of its eight channels, each with a sampling rate of 1.25 GS/s. The eighth input channel can also be used as an 8-bit digital input, optionally expandable with an additional 16 bits. “The Yokogawa DLM4000 is used to measure


currents of more than 1000 amperes and voltages up to just over 1,000 volts,” says Christian Neisse, head of development & construction industry at PCS: “For these measurements, we use Rogowski coils and six high-voltage probes. The Rogowski coils are used for evaluating the current waveform and the time profiles and for locating EMC problems. These can be simply inserted round a cable, so there is no need to disconnect the circuit, which with the thick lines used would be pretty expensive.” “Because these are three-phase systems, we usually have to measure three voltages and three currents simultaneously, as well as monitoring the ignition signals of the IGBTs. We therefore needed an oscilloscope with eight analogue channels and some digital inputs,” adds Mirko Grimberg, developer at PCS. “What was also important in this context was the high bandwidth to allow us to look at and record the fast transient signals.” A further benefit is the sophisticated triggering


options on the DLM4000, which allows PCS to record and produce a statistical record of intermittent anomalies. “We are also currently investigating the harmonics,” says Grimberg. “To this end, we measure the fundamental frequency of 50Hz and the harmonics up to 1MHz. An FFT analysis is performed for pre- compliance testing, and the data is then processed with Matlab software for further calculations. With a four-channel oscilloscope these measurements would be much more time-consuming and complex.”


Yokogawa Europe www.tmi.yokogawa.com T: +31 (0)88 464 1429


/AUTOMATION Guardian The


Emergency-stop push buttons


Just in case there is no time for de- lays. Danger is immediately stopped. The elobau emergency-stop buttons are extremely reliable and robust. The switches meet all current norms and standards and round off the machine safety program of elobau. In an emer- gency a single action prevents or limits damage. Beyond doubt our bouncer does his job.


Enter 22


Enter 215


www.e-stop-button.net

Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52