Exploration • Drilling • Field Services


Leak-free high-pressure piping systems


Esa Ranne explains that the right connection technique, accurate prefabrication and solid pipe support are the key factors that ensure leak-free piping.


prefabricated tube has to be dimensioned accurately enough. Finally, the supporting of the pipes must be solid enough. When these three factors are realised, the piping will be tensionless and stable, and there will be no excessive strain on the joints. GS-Hydro uses non-welded connection technology and delivers leak-free piping systems around the world. 3D technology offers a design according to provided diagrams and layouts. Strain (such as thermal movements) directed on fittings, clamps and piping can be estimated beforehand.


T


Choosing the right connection Te company’s GS-flange connecting system covers tubes with an outside diameter of 16 to 609mm, the highest allowed operating pressure being 690bar. Te standard production materials are carbon steel (zinc electroplated or hot dip galvanised) and stainless steel. When the wall thickness of the high-pressure pipe is less than 7mm, the flange is locked to the pipe by 37° flaring. When the wall thickness exceeds 8.5mm,


here are three major factors that must be managed in the planning and installation of leak-free systems. Firstly, the right connection technique must be selected. Secondly, a single


Te benefits of the GS-flange connection can also be seen with smaller size tubes. One benefit of the GS-flange with an outside diameter of 20 to 50mm compared to a fitting connection (eg, DIN, JIC) is their smaller size and, above all, lower tightening torque, which keeps the installation space reasonable.


Accurate dimensions GS-Hydro delivers prefabricated tube modules to the site, which are joined together for a complete piping system. Tis is done by, for instance, cold forming or machining instead of welding. Terefore, there will be no tension focusing on the material decreasing the dimensional accuracy.


Cleaning the insides of the tubes is easy and


Fig.1. GS-flange with 37° flaring. Its operating pressure is 50 to 420bar, the outside Ø 16 to 273mm and the wall thickness <2.5 to 7mm.


the flange is anchored with a retain ring. Te non- welded GS retain ring technique enables tubes with a diameter of 350mm and a 350bar nominal pressure. When the pressure is less than 40bar, GS-Hydro applies the 90° flaring technique. Te wall thickness can then be a maximum of 11mm and the tube diameter a maximum of 609mm.


there are major time savings as the installation time for a high-pressure connection can be made, on average, in a couple of minutes with the GS-Hydro technique. Additionally, the prefabricated pipes with bending, coatings, stampings, fittings, etc. can be fabricated in advance in workshops with the ideal machinery and by professional personnel. Together, this means that the cost savings are significant compared to welded piping fabricated at the installation site. l


For more information ✔ at www.engineerlive.com/iog


Esa Ranne is with GS-Hydro Finland in Hämeenlinna. www.gshydro.com


www.engineerlive.com 47


Fig.2.The lower tightening torque and smaller size of the GS-Hydro flange technique guarantees an easy installation even in tight circumstances.


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100