MULTI-OCCUPANCY BUILDING SUPPLIES AND CUSTOMER LV SUPPLIES ABOVE 100A:UPDATE


In response to changes to the Gas and Electricity (Internal Markets) 2011 Regulations, UK Power Networks is introducing a new standard for multi- occupancy buildings and a new standard for the connection of new services above 100A. These new standards will be effective across all three of its distribution network operator (DNO) regions – the Eastern, London and the South Eastern Power Networks. The introductory date of


these standards was intended to be the 1 January 2013, as published in ECA Circular 187 2012. This date has proven to be challenging to all parts of the industry, therefore, in consideration of its


partners and customers, UK Power Networks is delaying its introduction until 1 June 2013. The standards, EDS 08-0118


Supplies to Multi-Occupied Buildings and EDS 08-0143 Customer LV Supplies Above 100A, will remain available on UK Power Networks ‘Technical Information for ICPs and IDNOs’ webpage (http://library. ukpowernetworks.co.uk/library/ en/g81/Design_and_Planning/) to allow its industry partners an opportunity to review the upcoming changes in advance of the introduction, although all new customer connection quotes issued before 1 June 2013 will be based on the current and existing practices of the Eastern, South Eastern and London


Power Networks. In development since early


2008, the new multi-occupancy buildings standard will mean that UK Power Networks will no longer install or maintain any new rising and lateral sub- main cabling networks within a building. The PME earthing will only extend as far as the service intake cut out and with provision for metering of the individual properties within the building. This will impact many new build or renovation projects of flats, office buildings, shopping centres and any multi- use buildings sharing a common intake service. In future, responsibility for


the design, installation and maintenance of new rising


and lateral sub-main cabling networks within buildings will rest with the building landlord or building owners’ nominated building network operator (BNO). For new service connections


above 100A, there will be the introduction of air circuit breakers (ACBs) across the three regions. UK Power Networks will provide clear information on the requirements of the intake location or switch room size. Both standards are available


on the UK Power Networks G81 ‘Technical Information for ICPs and IDNOs’ page. n For more information, email Giuliano Digilio at giuliano.digilio@eca.co.uk or call 020 7313 4825.


60mm Deep Minimum Void


Fits Into Includes Technology


BENDING OVER BACKWARDS


The unique fl exi-driver feature makes the inceptor downlight ideal for installation into shallow ceiling voids. LIGHTING BY


call: 01827 63454


J0907 ECA March Ad - Inceptor Dimmable.indd 1 16 ECA Today March 2013


email: sales@scolmore.com visit: www.scolmore.com GROUP 14/02/2013 13:16:57


NOW


DIMMABLE VERSION


AVAILABLE


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64