original was held in place by four cables.
washers fastened, 4-10x32 nuts with washers fastened and 4-1/4” sheet metal screws. Instructions included.
CAT. NO. EACH 1E594
A259 $37.50
Belly band mount to replace the perforated strap cage assemblies.
CAT. NO.
EACH FM55
$42.15
When you wire two capacitors in parallel, the “mfd” rating becomes the total of the two “mfd” ratings on the capacitors and the voltage rating becomes equal to the lowest voltage rating on either capacitor.
find a three terminal rated at 35 “mfd” and 5 “mfd” @ 370 VAC and a separate 5 “mfd” @ 370 VAC two terminal capacitor. On the replacement capacitor between the “C” , “Herm” and “Fan” terminals the “mfd” rating is 5 “mfd”. Between “C” and “herm” the “mfd” rating is 35 “mfd”. If we use both capacitors we can put a jumper wire from the 5 “mfd” capacitors “C” terminal to the three terminal capacitor. We now have an “mfd” rating of 35 and 10 “mfd”. Many mfd combinations can be matched this way.