This page contains a Flash digital edition of a book.
Surveying - Replacement Window & Doorsets
General : Surveyor
Manufacturing Sizes: Due to temperature fluctuations, PVCu windows and
doors can expand and contract. This needs to be taken into account when
calculating the finished frame size in relation to the aperture. The table below
highlights the recommended deductions for the width and height of a frame.
Recommended Deduction for Width and Height of Structural Opening.
Material: Up to 1.5m From 1.5m to 3.0m From 3.0m to 4.5m From 4.5m
GRP 5 10 15 15
PVC-U : White 10 10 15 20
PVC-U : Non White 15 15 22 28
Timber 10 10 10 15
Steel 8 10 12 15
Aluminium 10 10 15 20
All dimensions in millimetres (mm)
These deductions are from the TOTAL width and height, and not “per side”.
The gap (tolerances) required for effective polyurethane foam fixing at the head is 10 - 15mm.
NOTE: When the overall width or height exceeds 3.0m, intermediate expansion joints may be
required.
NOTE: BS7412 limits window sizes up to 3.0m only.
Issue: 2 (January 2008) 10
Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70