PHAM NEWS | MAY 2026 36 Product Spotlight
Safe, chemical-free alternative for filling heating systems
German valve manufacturer SYR has produced an advanced combination valve for the automatic filling of heating systems. Eric Winter explains the benefits of the innovative solution that features a demineralisation cartridge and automatic system monitoring.
particularly with the rising installation of heat pumps, system designers and installers are seeking innovative solutions to maintain optimal cleanliness and water quality. Ensuring the longevity and efficiency of these heating systems requires new approaches, especially those that are environmentally conscious and chemical-free.
A
Up to standard A notable topic gaining momentum in the industry, especially with renewable systems, is the VDI2035 standard. This has long been the recognised standard in
s the UK heating market increasingly adopts low-carbon technologies,
Germany for chemical-free filling alternatives, designed to prevent damage in heating installations caused by poor water quality, corrosion, and scale formation. The key principle behind
Eric Winter NPD and innovation director for SYR Hans Sasserath GmbH & Co. KG
the VDI2035 approach is proactive water treatment. Instead of attempting to remedy poor water quality with chemicals after it has entered the system, installers treat the water beforehand. This process removes scale and stabilises pH levels, resulting in better control over water quality and significant environmental benefits. To ensure proper
functioning and a long service life for modern heating installations, the quality of the filling water is crucial— hence the creation of the VDI2035 standard.
Water hardness Water hardness is primarily determined by the concentration of calcium and magnesium salts. These minerals, known as hardeners, define the ‘total hardness’ of water, measured in the VDI2035 standard in °dH (degrees of German hardness) or mol/m3
. One
German degree of water hardness (1°dH) equates to
10 mg of calcium oxide or 7.19mg of magnesium oxide per litre of water. Additionally, one millimole of calcium and magnesium ions corresponds to 100mg of calcium carbonate (CaCO3
). The pH value measures the
acidity or basicity of water. For heating water, maintaining an alkaline pH between 8.2 and 10.0 is essential, as acidic water accelerates
t SYR will be exhibiting at this year’s Installer Show where visitors will have an opportunity to learn more about the 3228 All- in-One Connect and other new product developments
corrosion processes. The pH affects the protective surface layers on metals within the heating system, which serve as a natural barrier against corrosion. Aluminium components, such as heat exchangers and radiators, require a pH between 9.0 and 10.0 to avoid damage.
Filling procedures When filling a heating system with demineralised water, installers must consider several practical aspects. In UK domestic properties, the system is often filled via a filling loop or a similar arrangement integrated into the heating appliance. Complying with water regulations is essential, requiring backflow protection to class 3 for domestic and class 4 for commercial settings. Isolators must be provided on both the potable and heating water sides of the filling loop, and the loop must be disconnected after use. Permanent connection to
the mains is only permitted if a CA device (domestic) or BA device (commercial, RPZ) is used. The demineralisation system must be installed downstream of the filling loop. This can lead to a complex and time-consuming installation. However, SYR has simplified this process with the Filling Station 3228 All-in-One Connect.
Automatic monitoring The All-in-One Connect ensures smooth and effective operation of the heating installation by providing automatic monitoring of filling and water conditioning,
conductivity determination, special leakage protection, and an integrated RPZ valve for backflow protection up to fluid category 4. Thanks to electronic
monitoring and an integrated pressure reducing valve, the filling process is stopped once the desired system pressure has been reached. The filling frequencies are recorded, displayed in statistics and can be called up at any time. The initial system filling may also include the display of the total filling volume. The built-in leakage detection system will monitor the frequency of top ups to the system, and the amount of water used and if this falls outside pre-set parameters alerts are triggered. The 3228 All-in-One Connect
is Wi-Fi-enabled and comes with a LAN connection. The SYR app can be used to create, monitor, check and control a project. For example, the smart valve informs installers/ operators via push notification that the connected cartridge will soon be exhausted.
Maintaining efficiency As renewable heating systems, such as heat pumps, become increasingly popular, installers are motivated to seek improved methods for ensuring system longevity and sustained high efficiency. The chemical-free solution achieves this by offering lower long-term maintenance costs, eliminating the need for chemical storage and disposal, and providing a more environmentally friendly system overall. ◼
phamnews.co.uk/526/60
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40