Paul Sands of Stokvis Energy Systems reflects on the reasons social housing landlords are returning to the use of centralised heating systems
I
n recent years our social housing sector has ‘rediscovered’ an appetite for district heating after decades of
adverse publicity and seemingly cheaper alternatives had persuaded many landlords to replace the systems; normally with individual gas boilers. There was no single Eureka moment but
rather a steady stream of economic and technical reasons which emerged, all of which in some way pointed towards the benefits of district communal heating. The most prominent of these was the launch of the new Code of Practice on Heat Networks by CIBSE, as it set out in detail the way in which such schemes can and should perform, the way they should be designed and the very many different heat sources they can draw on. Even though domestic boilers have
improved dramatically in efficiency and reliability – thanks to condensing technology and much better control systems – for housing associations, there remains the elephant in the room. There is the logistical nightmare of annual gas safety inspections, with a percentage of tenants always reluctant to cooperate with access for the heating engineer. There was also the lifespan of most boiler types remaining around 10 years, making their whole life cost very high.
So we have to find the most efficient means possible of utilising the gas or other fuel that we do burn: and this can be demonstrated through properly specified district communal schemes either within a block of flats or across larger developments.
Buried deep within the CIBSE Code of
Practice is guidance on the sizing or capacity of systems. When looking at reasonably well insulated properties, it is the domestic hot water consumption, rather than space heating load which generally dictates the output of stand- alone boilers. Having to consider residents using more than one bathroom simultaneously as a
18 February 2018
tap is running in the kitchen sees boilers being routinely oversized. However, this tendency can be resisted, or at least mitigated in communal schemes. Specifiers of district heating schemes can not only calculate on a much lower average peak demand when considering 50, 100 or perhaps 500 homes, but they have the option to divide up the load between different technologies. They can meet the base load for a scheme using biomass or a bank of heat pumps; perhaps linked to boreholes or even a water source such as a river.
Solar thermal panels could also be
linked into this eco-friendly capacity, able to deal with demand on all but the coldest winter days at which point the system would then switch on a gas fired boiler. Combined heat and power or CHP is also proving popular and a couple of schemes unveiled last year will make use of “waste” heat from incinerators or industry. So, with a highly energy-efficient and hopefully green heat source identified, the other major task is distributing it effectively to residents which is where Heat Interface Units (HIUs) present the ideal answer. HIUs facilitate the exchange of energy between the district heating mains and the individual dwellings normally allowing the domestic consumption to be monitored or metered and isolated when maintenance work is necessary. Crucially, there is no annual gas safety inspection and the HIU can be mounted in a landlord cupboard, accessible from outside the dwelling, and even fitted with a wireless link so that the meter can be read remotely. Normally supplied as a custom- designed unit to suit a scheme’s particular requirements, Stokvis H-Series HIUs feature efficient plate heat exchangers to transfer energy to the dwelling’s private circuit. They can provide domestic hot water, as well as heating, either direct or via a cylinder. Response is rapid and reliable, while customers benefit from lower energy bills.
Stokvis Energy Systems’ Econoplate H2 units separate the district or communal heating system from the dwelling and provide indirect heating and hot water separated via two plate heat exchangers
Changes to benefit payments and funding levels from central Government are putting an increased financial strain on housing associations at a time when the demand for affordable housing is rising rapidly. Taken in tandem with the UK’s looming energy crisis, district heating schemes, featuring high efficiency and easy to manage HIUs, offer a valuable means of recovering control over stretched budgets.
www.heatingandventilating.net
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48