FILTRATION & SEPARATION FEATURE UNCOVER THE HIDDEN TRUTH


Many owners and operators of cooling towers and cooling systems believe that they have an effective and safe water system in place – but how safe are they really? John Wilson of Amiad Water Systems UK discusses some of the hidden truths...


B


y nature of their action, cooling systems may suffer considerable levels


of system contamination. This can be caused by suspended solids in the make- up water, the ‘scrubbing action’ of cooling towers, or by process leaks encouraging microbial activity. With operators wanting to employ what


they believe to be a ‘quick fix’, what we regularly see are operators focussing on just one aspect of the water treatment regime. Little do they realise that this could in fact make the situation worse as is pointed out by the Health & Safety Executive’s (HSE) own advice: “An appropriate cooling water treatment


programme must be capable of controlling not only legionella and other microbial activity, but also corrosion, scale formation and fouling, and include appropriate measures, such as regular physical cleaning and disinfection, to maintain the system’s cleanliness. This is very important since these aspects are often interrelated and failure to control one aspect will often lead to other problems and will increase the legionella risk.” In reality, what we commonly see are


cooling system installations that have focused upon compliance, with operators throwing extensive chemical treatments at the problem in the belief that this will ensure they do not fail microbiological tests. Rather than considering the efficiency or indeed the implications of running with a heavily contaminated system, conventional chemical techniques employed may involve adding inhibitors to control corrosion and scale formation, biocides to control microbial growth and dispersants to control fouling. Here lies the hidden and often ignored


issues of poor energy transfer, blockages and system shutdowns that result from a poor-quality cooling water being circulated. To help combat these, many operators


feel safe having installed traditional technologies such as side-stream filtration, where a volume of recirculating cooling water is passed through a ‘side- stream’ loop to remove these contaminants from the water and in so doing reduce overall loading of solids. Typically, these are kinetic or centrifugal separators, or other technology such as self-cleaning screen filters, disc filters or





even conventional media filters. As a standard practice such systems are then combined with chemical treatment. Fitting a side stream filtration solution


will improve performance, however, we need to fully understand the implications of what lies within the cooling water before a correct side stream filtration solution can be implemented. Generally, when you look at a cooling


system you will find that 80-90% of the particles are less than 10 micron in size and it is these particles which lead to most of the problems. In most systems the process cooling


water is passed through a system of pipework and then if a cooling tower is present, it is passed over the cooling area of the tower, or through a chiller or heater. Because pipework material surfaces are not completely smooth, larger particles, having a larger surface area, collect into a mass which is swept along through the system by the water flow. Smaller particles, typically less than 5-


6micron, affix themselves in the surface inclusions and roughness. What you now have are smaller particles lodged in the pipework and system cooling surfaces. Some may well be killed off by chemicals but they still hold their position, often building up to give a smooth internal pipe surface known as biofilm. And it gets worse. Underneath the biofilm remains a rough surface area which is now colonised with live bacteria. The bacteria is protected from the chemicals and colonises due to being kept warm and fed on a continuous basis. Where biofilm has formed you can expect major problems with plant and equipment as well as the stability of the cooling and there is increased risk of breaching present HSE laws. The question is should we filter to less


Effective side stream filtration should be based upon selecting the most appropriate technology for the application and ensuring that it can effectively remove the type of solids in the water


than 5 micron? Well, not necessarily. This is where you need to get some


meaningful water analysis done. It is quite common for operators to occasionally do a Total Suspended Solids (TSS) test which only tells you how much solid particulate you have in the water. What you really need to understand is the volume of solids and the size of particles that are present. A Particle Size Distribution (PSD) will help you understand what volume of solids you have within the cooling water. When you look at a PSD you will often see that many of the solid particles are very small and as low as 1 micron in size. However, it is not just particle size that matters but the volume of the particles. For example, you may find your particle count for <5 micron particles is very high but this only represents a small fraction of the volume.


Effective side stream filtration should be based upon selecting the most appropriate technology for the application and ensuring that it can effectively remove the type of solids in the water. Here is a short list to consider when choosing a side stream filtration and the options available: • What is the nature of the particles?


Organic or inorganic? • How good a level of filtration is really needed? • How much space is available? • Is the site sensitive to water losses? • Do you need uninterrupted filtration? • What would be the cost of


Illustration of typical filtration solutions used in cooling towers


maintenance and the impact to operation? Like most types of equipment there is a


wide choice of technology from which to choose with each type having its own distinct pros and cons. Options include traditional sand filters, automatic screen filters, and high efficiency media filters. Ultimately, the best side stream filtration system is the one that provides the best possible return on investment by improving plant efficiency, reducing both operational and maintenance costs and meeting HSE requirements.


Amiad Water Systems UK www.amiad.com


PROCESS & CONTROL | MARCH 2019 7


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52