Calibration M
onitoring the performance of large rotating plant is an essential part of proactive maintenance helping to avert problems whilst prolonging the life and
efficiency of plant and equipment. However, what about the servicing and calibration of the actual condition monitoring systems? To provide the function, efficiency and true
value, the monitoring systems themselves require regular calibration and servicing. For example, an incorrectly calibrated sensor may not provide the accurate alerts you need to replace wearing or faulty components in time to prevent downtime and may even invalidate your insurance. Condition monitoring specialist Sensonics offers
not only a wide range of industry leading vibration, temperature, position and rotational speed systems for large rotary plant, it also providea calibration, servicing and spares which will help you get the best value from your investment. The company’s UKAS traceable calibration and maintenance services can be applied to all sensors and monitoring equipment, either on-site or on a return-to-base service. Servicing options include on-site
maintenance anywhere in the World, along with fully traceable, return-to-base repair carried out by experienced maintenance engineers with the required qualifications and approvals. This includes working on both military and nuclear sites.
Maintain anD calibrate Your MacHine Monitoring sYsteMs
Early addressing of minor issues can prevent
these developing into major faults which can lead to disruptive unscheduled downtime, the associated unbudgeted expense, whilst reducing your equipment’s lifetime repair costs. Furthermore, planned servicing can help to increase productivity and ROI in addition to keeping your monitoring system in-tune with the latest technological advances in hardware and software. Sensonics also offers spares and replacement
parts for all monitoring systems including older systems (upwards of 30 years) with quick turnaround and stock agreements available for
rapid dispatch. To complete its service and maintenance package the company also offers parts-only ordering, along with installation and commissioning, scheduled replacement for obsolescent or end-of-life products. Thanks to over 50 years’ experience in
supplying, commissioning and maintaining monitoring systems across a wide range of industries means Sensonics can provide an outstanding package of servicing, calibration and maintenance packages for all types of systems.
sensonics T 46 Mobile HigH-precision pressure calibrator
he KAL 100/200 is a high-precision pressure calibrator suitable for both stationary and mobile installation. It enables on-site calibration of pressure measuring systems, for example differential pressure measuring systems in clean rooms or air-conditioning systems, or blood pressure
measuring systems in hospitals. Due to new product features in the KAL 100/200 series 3, on-site calibration is now even more convenient. The KAL family unifies the integrated, automatic pressure generation
of positive and negative differential pressures for the specification of the calibration point with high-precision pressure measurement in one device. The automatic zero point adjustment achieves high accuracy and long-term stability, even with the smallest measuring ranges. The easy menu navigation, available in five languages, makes it easy to set calibration points and define measuring spans. The new switching power supply integrated in the series 3 protects the instrument against over- and undervoltage, regardless of the
area of application. The modern and lightweight all- voltage power supply provides automatic adjustment of the voltage supply, allowing the KAL 100/200 series 3 to operate between 85VAC and 264VAC. Country- specific differences in voltages are regulated and the calibration device can be safely used worldwide without further configuration. In addition to these changes, the unit now displays the time of the last
calibration when it is switched on, enabling the user to check the calibration intervals more easily and ensure correct performance. The battery level indicator was also designed to be more user-friendly. In addition to the factory calibration certificate which is provided as standard, a calibration certificate according to DKD-R 6-1 is available.
halstrup-walcher
www.halstrup-walcher.de January 2023 Instrumentation Monthly
www.sensonics.co.uk
Feature sponsored by
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82