SPECTROSCOPY
cooling and high-sensitivity back-thinned CCD detector. Additionally, the AvaSpec- Hero also boasts an extremely wide dynamic range of 40,000:1, which makes it much easier to detect the subtle variations which can often mean the difference between healthy and diseased tissue.
SILICON WAFER TESTING Another up-and-coming Raman application, particularly in the photovoltaics industry, is the monitoring of both stresses and crystallinity in silicon wafers. Pure crystalline silicon is far more effective than its amorphous counterpart at converting light into electricity, and because of this, it is used in the production of over 85% of the commercially available solar cells on the market today. Crystalline silicon is capable of producing conversion efficiencies of ~20%, while by comparison, amorphous silicon solar cells offer less than 10% efficiencies as of today. As a result, quality control of these devices is critical at the wafer level to ensure peak performance. Raman spectroscopy is an ideal tool for the job, since the effect is polarisation sensitive, the orientation of the silicon molecular structure will affect scattered Raman spectra. For pure crystalline silicon, there is only one allowed molecular vibration resulting in a single narrow spectral peak at 521cm-1 but in the case of amorphous silicon where the molecules are randomly
oriented the band shifts and broadens resulting in an extremely wide peak centred at 480cm-1. Additionally, even if the wafer is made of pure crystalline silicon but has undergone stresses or strains during the manufacturing process, it will also decrease the solar cell’s efficiency and lifetime. Tis stress results in the molecular bonds being dampened causing slight changes in the vibrational frequency that can be detected by looking at the shift in the Raman peak. For both of these applications, sensitivity is usually not a concern due to the large Raman cross-section of silicon, but high resolution is critical to detect the small shifts in the 521cm-1 peak from stresses and strains. It is also important to note that silicon is unique for having a photoluminescence peak in the near-infrared, making it preferable to use visible wavelength excitation lasers, further increasing the Raman scattering efficiency of the system. As a result, it is recommended to use the AvaSpec- ULS2048x64-TEC, high-resolution TE cooled spectrometer, which is capable of 3cm-1 resolution in the visible range of the spectrum. Avantes’ high-speed electronic triggering, data transfer rates and analogue and digital I/O capabilities further aide in this unit’s ability to seamlessly integrate into a high-speed wafer inspection system.
INCOMING INSPECTION Te last application to be explored is incoming material inspection for
pharmaceutical and nutraceutical manufacturing, which uses the same fingerprinting ability of Raman spectroscopy as described in the biomedical section above. Over the past 10 years this application has, in part, led to the explosion of handheld Raman systems that can be seen on the market today because of its ability to rapidly speed up material verification process allowing raw materials to pass from the quarantine area to the production floor quickly. Tis is typically accomplished by integrating the laser, spectrometer and data processing unit all into a single handheld device with embedded chemometrics for verifying the identity of active pharmaceutical ingredients (APIs), excipients and other pharmaceutical ingredients. Raman is ideal for this application because the laser can be focused through optically transparent packaging allowing for the contents to be analysed without ever opening the product and exposing its contents to the environment. For integration into a handheld
instrument, size is one of the most critical design considerations, which is why the AvaSpec-Mini-2048CL is the spectrometer of choice for many handheld instrumentation manufacturers. Te AvaSpec-Mini weighs in at only 175g at a compact size of just 95mm x 68mm x 20mm, which is roughly the size of a deck of playing cards, and because of the highly efficient 2048-pixel CMOS linear array detector, this unit draws less than 2.5W of power. Te AvaSpec-Mini is produced with the latest in automated production technology, providing excellent unit-to-unit reproducibility and temperature stability, which is critical for customers who are looking to for the ability to transfer methods from one handheld instrument to another.
FINAL THOUGHTS Although the three applications discussed above are far from the only Raman spectroscopy applications in which Avantes’ miniature spectrometers are integrated, they should serve to provide a framework that a systems integrator can use when deciding which spectrometer would be best for their particular application
Doctor performing an endoscopy procedure
38
www.scientistlive.com
Janel Kane is with Avantes.
www.avantes.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72