search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
Environmental Analysis & Electrochemistry


Automated Environmental Titration and Multi-Parameter Analysers


The new MANTECH MT series AM400 autosamplers from QCL save space and lower the cost per sample. The analysers can be configured as a simple pH system or with up to eight parameters. Systems are tailored with off-the-shelf modules to meet requirements for sample volume, parameters and sample size.


The MANTECH MT series autosamplers are optimised for water, soil, food and beverage analysis and each system is fully automated for up to 720 samples in a single batch. Advanced features include Titrasip™ automated pipetting allowing two or more titration methods from a single sample cup, and IntelliRinse™ to prevent cross contamination between samples.


The systems are controlled by MANTECH Pro lab automation software. Easy-to-use it includes a variety of features to improve database sharing and management, automation of controls and alerts, hardware and software communication, shortcut customisations and more.


More information online: ilmt.co/PL/j4Qg and ilmt.co/PL/RyMR 57600pr@reply-direct.com


Legionella pneumophila Test Published as ASTM International Standard


ASTM International is an international standards organisation that develops and publishes standards applicable to a wide variety of industries. There are over 12,500 global ASTM standards, developed and reviewed by over 30,000 technical experts from 140 participating countries.


Global water microbiology specialist, IDEXX, has announced that the Legiolert® test, for the rapid detection of Legionella pneumophila, has been published by ASTM International as ‘ASTM D8429-21: Standard Test Method for Legionella pneumophila in Water Samples Using Legiolert’.


This latest standard inclusion follows Legiolert having been specified as a recommended method in the by the UK’s Standing Committee of Analysts’ ‘blue book’ publication, ‘The determination of Legionella bacteria in waters and other environmental samples (2020) - Part 2 - Culture Methods for their detection and enumeration’. Legiolert is also recognised with AFNOR certification for hot and cold sanitary water and cooling tower water (Reference No IDX 33/06 06/19).


A liquid culture method, Legiolert was launched in Europe and North America by IDEXX in 2017 as a highly sensitive method for the confirmed detection of Legionella pneumophila (the primary cause of Legionnaires’ disease) in water, delivering results up to seven days faster than traditional ISO culture testing methods.


There are more than 10 peer-reviewed papers that have highlighted the superior performance of Legiolert when compared to the standard method for detection of Legionella pneumophila. The ISO 11731 method has a number of limitations including a significant false negative error rate which can result in undetected contamination and consequent risk to human health. In contrast, Legiolert is a culture method which is both accurate and easy to use.


More information online: ilmt.co/PL/yjjB and ilmt.co/PL/drrB 57479pr@reply-direct.com


QuPPe Method for LC-MS/MS Analysis of Polar Pesticides


The European Union Reference Laboratories (EURL) provide guidance to food safety labs around the world. That guidance can take the form of published methods that help labs looking to develop their own analytical tests, which can be particularly important for challenging analyses like monitoring highly polar pesticides in food. To face this challenge, EURL for Single Residue Methods (EURL-SRM) has published, and continues to update, the Quick Polar Pesticides Method (QuPPe).


Version 12 of the QuPPe-PO Method for products of plant origin includes an approach using Restek’s Raptor Polar X column for the analysis of a wide range of polar pesticides using LC-MS/MS in negative ESI mode.


Restek is proud to have its Raptor Polar X column undergo the significant evaluation conducted by EURL-SRM and then be included in this collection of methods, which are aimed at protecting consumers from harmful pesticides in food. The method can be accessed here: ilmt.co/ PL/ORyk


The Raptor Polar X LC column was specifically designed to address the challenges of LC-MS/MS analyses of polar compounds. It provides excellent retention and separation of polar compounds through its unique hybrid phase chemistry, offering the best of HILIC and ion-exchange retention mechanisms, while still equilibrating quickly and using MS-friendly mobile phases.


Learn more about the Raptor Polar X column or contact your local Restek representative today. More information online: ilmt.co/PL/gOMG


56737pr@reply-direct.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56