Digital DosingTM


– Unique Solutions for Challenging Dosing Processes


Disinfection, neutralisation, precipitation and flocculation are essential physical and chemical processes of water treatment and wastewater recycling.


Modern, highly efficient chemicals have to be used economically and with


minimal impact on the environment. Some of these chemicals are very difficult to handle, and this overstrains conventional dosing pumps. These challenges can be met by digital dosing pumps with modern drive technology and control software.


Capacity setting


100% SlowMode Discharge - Suction Discharge 50% - Suction Discharge 10% - Suction 10% 50%


Discharge Suction


The chemistry in water treatment, water and wastewater recycling has experienced a huge development during the last 15 years, and this poses a challenge for today’s dosing technology.


Additionally, more and more complex applications require intelligent dosing pumps with new drives or new control and adjustment mechanisms to simplify the operators’ job. This in turn ensures reliable, cost-effective, and high-precision processes.


Grundfos Alldos have accepted and met these challenges with their digital dosing pumps. These offer state-of-the-art drive technology and new dimensions of user-comfort, energy efficiency and dosing characteristics.


Higher requirements in control tasks and process reliability


With conventional dosing pumps, the dosing quantity can be adjusted by changing some parameters such as stroke length and frequency. These factors have to be combined in the right way in order to get the right dosing performance. Furthermore, the adjustment range is usually limited. As a consequence, the correct pump type has to be selected for each single application. Increased control requirements, such as dosing in proportion to the volume via 0/4-20 mA or dosing control feedback to a central control system, can only be realised with supplementary installations and accessories.


The new digital dosing pumps put an end to complex adjustments via stroke length and frequency. Stepper motors and EC drives with multi- sensor control circuits optimally fulfil the requirements due to variable, adjustable suction and dosing stroke speed. This unique feature ensures an optimal dosing characteristic and high precision even at a turndown ratio up to 1:1000, e.g. the DME 940-4 easily achieves a flow range from 1.2 to 940 l/h.


Further integrated standard features of digital dosing are: direct adjustment of the required capacity in ml/h, l/h, or gph, volume- proportional dosing via ml/pulse or 0/4-20 mA scalable analogue control, and time- or pulse-controlled batch dosing.


Thanks to the wide flow range and flexible control options one single pump type can be used flexibly within one application. This keeps investment and maintenance costs at a low level.


AUTHOR DETAILS Matthias Ulmer


Product Manager Dosing Pumps Alldos Eichler GmbH - A member of the Grundfos Group Reetzstr. 85, 76327 Pfinztal Country: Germany Tel: +49 (0)7240 61 0 Fax: +49 (0)7240 61 177 Email: mulmer@grundfos.com Web: www.grundfosalldos.com


The FlowMonitor and the Dosing Monitor detect – without any mechanically actuated parts – problems such as air-bubbles or system overpressure, and automatically display an error message. The latest development in this area is the AutoCal function, also based on pressure sensor technology. Now, even system pressure fluctuations have no influence on the dosing accuracy, as the motor speed is adjusted accordingly. This cost-effective solution increases the process reliability.


Precise dosing of highly concentrated chemicals to reduce both costs and environmental impact


The higher the concentration of the chemical, the more important is the dosing precision in order to reduce costs and environmental impact. Conventional dosing pumps fail through lacking precision. This can lead to over- or underdosing and to suction problems when dosing minimum volumes.


Duration Duration Duration Duration


The very high precision is a result of a combination of factors: digital input of the dosing capacity without stroke adjustment, a calibration function to adjust the pump according to the properties of the dosing liquid, a positive crank drive of the diaphragm as well as an optimised dosing head and valve geometry. These are the key factors for environmentally friendly and cost-efficient dosing of chemicals.


Failure-free dosing of highly degassing chemicals


Dosing of degassing liquids usually results in an airlock in the head of conventional dosing pumps. Stoppages caused by gas bubbles result particularly from the heavily pulsating suction and dosing characteristics as well as the reduced stroke volume due to stroke length adjustment.


The new drive technology allows optimum control of suction and dosing stroke speed without changing the stroke length. The position of the diaphragm and therefore the volume flow are continuously controlled. The decisive advantage here is the fact that the suction phase is always performed with the full stroke volume.


The smaller the desired volumetric flow in relation to the maximum flow rate, the more continuous and smoother is the dosing characteristic, resulting in lower pulsation in the dosing system. This is very important to ensure smooth dosing of degassing liquids especially in installations that require long suction lines.


Reliable and precise dosing of viscous chemicals


Viscous polyelectrolytes are increasingly applied as flocculation additives in wastewater recycling processes. To avoid mixture gaps, it is essential that the dosing pump delivers precisely the required quantity into the process.


A combination of precise control of the suction speed, special valves, nominal widths and the positive drive of the dosing diaphragm enables proper handling and precise dosing of viscous media without the need for further gearing variants.


This is achieved by using the “Anti-Cavitation” or “Slow-Mode”, which


permits media with viscosities up to 3000 mPas to be dosed reliably with high precision. Especially the pump models between 60 l/h and 940 l/h are ideally suited for these applications.


Conclusion


Grundfos Alldos took a big step forward in Digital DosingTM. With digital pump technology, the water treatment and industry business is well- equipped to meet the upcoming challenges.


The advantages at a glance: • Precise, trouble-free and reliable dosing • Energy-saving and cost-efficient • User-friendly handling and operation • Extensive control and monitoring functions • High turndown ratio up to 1:1000


• Dosing capacities from 0.0025 to 940 l/h with only 9 models


Further information regarding Grundfos Alldos Digital DosingTM pumps can be found at: www.grundfosalldos.com


IET


Annual Buyers Guide 2010


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136  |  Page 137  |  Page 138  |  Page 139  |  Page 140  |  Page 141  |  Page 142  |  Page 143  |  Page 144  |  Page 145  |  Page 146  |  Page 147  |  Page 148