search.noResults

search.searching

dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
Analytical Instrumentation VUV PIONA+TM Automates the Analysis of Olefin Classes in Fuel Stream Samples


VUV Analytics, Inc. (Austin, TX) has expanded the olefin compound classes that can be characterised in gasoline range samples by VUV PIONA+TM


cycloolefins, and conjugated hexadienes. After an initial setup step in VUV AnalyzeTM


via ASTM D8071 to include non-conjugated diolefins, conjugated diolefins, data processing software,


these olefin sub-categories can be added to the automated post-run report along with total amounts of paraffin, isoparaffin, olefin, naphthene, and aromatic (PIONA) hydrocarbon classes. VUV AnalyzeTM


also allows further customization of the report to include specific analyte speciation and other sub-classes such as di-aromatics.


Olefins, especially conjugated diolefins, are known to cause fouling of refinery processes and to negatively impact product quality. Conjugated diolefins are monitored in fluid catalytic cracking (FCC) gasolines because they are highly reactive to polymerisation and plug downstream refining processes. Legacy methods for conjugated diene characterization vary in their respective levels of complexity, analysis time, and accuracy. For example, UOP-326 (maleic anhydride method) takes more than 3 hours to complete, does not completely react with some conjugated dienes, can be interfered with by alcohols, and is difficult to automate. In contrast, ASTM D8071 applies to all finished gasoline samples, has successfully been used for other gasoline-range sample types, has a GC run time of approximately 30 minutes, and includes the automated analysis of relative PIONA hydrocarbon totals.


ASTM D8071 uses straightforward instrumentation: a gas chromatograph, a standard 30m nonpolar column, and a VUV detector. The method provides complete PIONA compound class characterization in a single measurement. It utilizes the similarity of VUV spectra within compound classes to determine group composition within a sample, while also using unique VUV spectra to speciate individual analytes such as ethanol, iso-octane, benzene, toluene, ethylbenzene, xylenes, naphthalene, and methylnaphthalene compounds. ASTM D8071 is also enabled by the ability of VUV AnalyzeTM to deconvolve co-eluting species and provide accurate determination of relative hydrocarbon group concentrations in mass or volume percent.


VUV AnalyzeTM software implements


equations and fit procedures that result in the deconvolution of absorbance spectra that contain contributions from multiple species. It is capable of binning and storing response contributions from each deconvolution analysis and reporting a combined total response at the end of the analysis. Its data processing includes a database library of reference spectra, compound class information, density, approximate retention index values, relative response factors for each hydrocarbon class, and relative response factors for individually reported compounds.


The customisation of VUV PIONA+TM for olefin


sub-categories was recently demonstrated on a gasoline range sample with high olefin concentration. ASTM D8071 was applied to this sample, and VUV AnalyzeTM


reported 37% total


olefin concentration that included 0.2% non- conjugated diolefins, 0.3% conjugated diolefins, 4.5% cycloolefins, and 0.1% conjugated hexadienes. Olefins that do not belong to these sub-categories such as trans-2-heptene were accounted for in the remaining 31.9% reported as total olefin %. Figure 1 shows a time slice in the VUV AnalyzeTM


post-run analysis window


that highlights the deconvolution of an olefin, conjugated hexadiene, and cycloolefin. Another recent investigation used this sub-category characterisation capability to determine the non- conjugated diolefin, conjugated diolefin, and cycloolefins content of coker naphtha samples. VUV PIONA+TM


via ASTM D8071 is an effective


method for monitoring the occurrence of problematic olefins and informing fuel blending decisions during refining processes.


For more detailed information please visit our website at www.vuvanalytics.com or contact us at info@vuvanalytics.com.


For More Info, email: email:


For More Info, email: email:


VUV VE R I F I ED 46272pr@reply-direct.com vuvanalytics.com


Unambiguous identification & quantitation of compounds, including isomers


Shorter GC runtimes


Easy deconvolution and quantitation of co-eluting analytes


No calibration required - 1st principle detection technique provides a predictable linear response


19


Figure 1: A time slice in the VUV AnalyzeTM


tion of an olefin, conjugated hexadiene, and cycloolefin. VUV AnalyzeTM along with total olefin mass %.


post-run analysis window that highlights the deconvolu- reports olefin subcategories


VUV Absorption Spectroscopy.


GC detection in a whole new light.


Making Vacuum Ultraviolet absorption spectroscopy available to the general scientifitic community for the first time. As in, ever.


Universal, yet selective detector with very sensitive spectral response


OCTOBER / NOVEMBER • WWW.PETRO-ONLINE.COM


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52