OILS & LUBRICATION


devices through a progressive or single- line lubrication system.


Lubrication for the pitch open gear can also be supplied via SKF pumps for the rotary application. Lubrication pinions are used to apply grease precisely to the area of contact on the drive pinion or the pitch open gear, and evenly lubricate the entire cog width.


An electrical grease pump introduces lubricant into the yaw bearing via progressive or single-line metering devices. Automatic lubrication achieves a sufficiently thick lubricant film to prevent excessive wear and the ‘stick-slip’ effect upon turning the nacelle. The automatic lubrication pinion meshes precisely with the gearing, distributing the lubricant uniformly in the area of contact across the entire cog width. Used grease is removed by a lubricant collector and delivered to a reservoir to prevent spillage on the nacelle floor, improving worker safety. The main bearings of a wind turbine


are subject to severe forces and usually require large quantities of lubricant. For stationary operation, a stirring and fixed paddle in the pump’s reservoir


is sufficient. The automatic lubrication system continually supplies grease to the main bearings even while in motion. The gearbox is lubricated and cooled by oil, which is recycled via filters. The oil can be electrically heated to achieve an optimal start-up temperature for the lubrication cycle in conditions of low ambient temperatures. Flow limiters maintain the prescribed oil volume flow independent of pressure and temperature changes and these can provide feedback on the current flow rates to the condition monitoring system.


CONTROL AND MONITORING


Taking SKF’s condition-based lubrication concept as an example, here we have the interface between a condition monitoring system (SKF WindCon, in this case) and the automated lubrication systems (SKF Windlub or Lincoln Quicklub, for example). Combined, these elements are able to track and control lubrication system health, pump status and grease levels, as well as alerting operators to failures such as empty or blocked


lubricant pumps or fractured feed lines. This monitoring data can also be uploaded via internet connections to remotely located diagnostics centres, operating globally 24/7, for expert analysis and reporting.


By logging and tracking deteriorating component conditions in real-time, condition-based monitoring allows maintenance decisions to be based on actual machine conditions, rather than arbitrary maintenance schedules. Along with the possibility that maintenance intervals can be extended, the system provides a powerful tool for managing day-to-day maintenance routines and consolidating high risk, costly maintenance activities.


SKF SCAN/CLICK


MORE INFO


www.windenergynetwork.co.uk


17


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116