42 May / June 2016 UK Made Gas Chromatograph


The 200 Series Gas Chromatograph from Ellutia is an extremely compact, energy efficient yet powerful analysis tool. Designed and manufactured by Ellutia in the UK the 200 Series GC offers all the analytical performance of a much larger conventional system but with a footprint of just 41 x 32cm and power consumption of just 800 VA.


The 200 Series GC is a single channel instrument that comes installed as standard with a split/splitless injector and full electronic carrier gas control. A Choice of detectors are offered including FID, TCD, ECD and FPD, allowing for most applications to be run. The oven can accommodate capillary columns up to 60m in length as well as packed columns using the optional adaptors.


The 200 Series GC column oven is heated by a unique, innovative and award winning heater design. The flow through heat exchanger unit means the design of the GC could be kept extremely compact and energy efficient without sacrificing performance. The


oven can be temperature programmed with up to five settable ramps up to maximum temperature of 300°C.


A Range of accessories are available including Liquid and Headspace autosamplers, gas sampling injection valves, integration software and hardware and PC method download Software. Are available to further enhance the capabilities. For more information visit: http://www.ellutia.com/200Series.html


Low Adsorption Autosampler Vials


Supelco’s Low Adsorption (LA) vials are manufactured using a process that decreases the number of hydroxyl groups on the vials glass surface, significantly reducing surface activity while improving analytical quantitation and minimising pH shifts in the sample. This same process also removes unwanted surface metals such as sodium and boron that can contaminate samples and interfere with trace analysis. Unlike other methods used to decrease vial surface activity, the elimination of surface activity in LA vials is integral to the manufacturing process and is not a chemical surface treatment.


Vial Attributes


The vials, caps, and septa that come in contact with the sample are a critical component of a successful analysis. There are several factors to consider when selecting an autosampler vial.


* Lack of Interference – The vial and closure must not interfere with the sample being analysed. They should not leach out any chemicals, change the pH of the sample, or adsorb the sample


* Proper Fit – The vial and closure must fit into the autosampler perfectly. The vial/closure opening must be in the same place during each injection or the needle will be damaged. Needle damage causes wasted instrument downtime.


* Good Seal – The closure must seal properly to protect the contents and prevent evaporation. Some closures do seal better than others. However, choice of closure depends on volatility of the sample, duration of storage and analysis, and ease-of-use.


* Correct Septum Must Be Used – The septum must be inert and work with the needs of the analysis. If it is used for multiple injections, it must re- seal correctly. It must not core when a blunt needle is used. It should be soft or have a slit if used with a fine gauge needle.


Component Testing


The vial system consists of three main parts: vial, septum, and cap. Extensive testing is done to confirm the specifications for each product are met.


* Vials – Only Type 1 borosilicate glass is used to make Low Adsorption products. Clear vials are produced from Grade A, 33 expansion glass. Amber vials are produced from Grade B, 51 expansion glass because 33 expansion glass is not available in amber. Tight tolerances on all critical physical specifications are controlled to make sure the highest quality is delivered each time. These specifications include height, diameter, neck thread, and bottom thickness.


* Septa – Septa are post-baked to provide the lowest level of extractables in the industry. The softness is measured for batch to batch consistency. All bonded septa are measured to certify bond strength reliability. The PTFE/silicone and modified PTFE/silicone septa are manufactured, conditioned, and then tested by GC/MS to ensure they have the lowest level of extractable in the industry.


* Caps – Caps are made from the finest grade of plastic available. Plastic components are manufactured using virgin resin that is tested for low levels of contamination. In addition, caps are moulded and batch measured to ensure fit, thread specification, and overall dimension.


View the low adsorption vial product list. For more information visit: www.sigmaaldrich.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56