BASIC SYSTEM COMPONENTS Measuring Unit with ODAC® Diameter Measuring Heads


A robust, welded structure ensures protection of the laser heads against dust, scale, splashes and heat. • Drive system for up to 100rpm • Fully contact-free power and signal transmission • Easy exchangeable protection glasses • Temperature control system • Diagnostic outputs for checking the video signals • Cooling for OD's up to approx. 30 mm (1.2 in.) by air only. Over 30 mm (1.2 in.) additional water cooling is required.


ODAC® 100 / 160 high-tech laser measuring heads (inside the measuring unit) • 1 emitter + 1 receiver for each head • Fully synchronized scanning between the heads • Principle: Laser scanning, 2000 measurements/s • Calibrated Single Scan (CSS) • Light source: Solid state laser, class II


Filter/Blower Unit GE 5-2


Providing filtered air at high volume to purge the laser shutter and for general cooling of the measuring unit. 3kW, 1350m3


/h (47,600cu. ft./h).


Local Processing and Operation Unit LPO


It forwards all pre-filtered measured values and transmits the data via a single fibre optic cable to the main control unit CPO. • Inputs for mains supply, measuring unit, pyrometer (optional) • PLC controller • Built-in cooling unit


Central Control and Operating Unit CPO


For up to 4 measuring units of the SMR (rotating), SMO (oscillating) or SMS (static) models. • Industrial embedded PC without fan in a 19" drawer (height = 8HU). Operating system on solid state disk, i.e no need for UPS unit (fail safe).


• Inputs/outputs: VGA for screen/keyboard/mouse, fibre optic connection to LPO unit, ETHERNET for customer (TCP/IP), USB for printer or other peripherals, RS-422 for giant displays, relay outputs for alarm etc., digital inputs (8) and outputs (4)


Software – Basic & Optional Packages


The sophisticated STEELMASTER software packages guarantee high flexibility in general, future safe upgrading, case specific solutions, personalized configurations, connectivity, process transparency.


Remote repeater screen for mounting and operation up to 150m (490ft.) • Remote giant display (2, 3 or 4 groups of 5 digits) • Pyrometer for conversion to cold values (20°C / 68ºF) • Traversing system for positioning or withdrawing of the measuring unit • Air cooler or heater for cooling and/or heating of blower air • Water cooling system (heat shield with circulating water) for product diameters exceeding 30mm (1.2in.).


ACCESSORIES 4


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40