TECHNOLOGY IN ACTION ADVERTORIAL
ARCOL RW Capacitor Discharge Resistor is Quick and Easy to mount
U
Intelligence and Reliability at a Great Price
I
f you are considering upgrading your soldering equipment
and trying to keep to a sensible
budget, then the new ATTEN soldering stations are just the answer.
ST-80 Soldering Station with 60W and 100W models to follow. With three separate
Somerset Solders are now stocking the 80W 220V programmable
temperature settings, a temperature range of 150°C to 480°C, the ST-80 is suitable for both Lead Free and Leaded soldering. Rapid heating and quick temperature recovery combined with a power down mode for solder tip life extension make this an attractive product in more ways than one. The temperature controller unit and soldering iron hand piece have been designed in an appealing two tone finish and the construction is both modern and functional. Priced at £115 ex VAT and supplied with 4 Free Soldering Tips.
Somerset Solders Ltd u 01761 233230 u
www.somersetsolders.com
enter 824
K based ARCOL Resistors, market leading specialist resistor
the
supplier, announces the availability of its RW Discharge Resistor. This wire- wound resistor is designed for quick and easy mounting on to
capacitors
and is typically used as a discharge or balancing resistor.
Discharge resistors are routinely connected
across large value output
capacitors found in electrical and electronic equipment which may store dangerous levels of energy after the equipment has been turned off.
Providing a safe discharge avoids any hazardous conditions when connecting other equipment or during service or repair. Balancing resistors are used when a number of capacitors are connected in series to ensure voltages across any individual capacitor does not exceed its maximum rating.
The ARCOL RW discharge resistor provides simple to fit screw mounting, is rated up to 22 watts, has a wide operating temperature range and is RoHS compliant. Three power ratings are available 10W, with ohmic value range of 1-15kΩ, 13W with values from 1-2kΩ and 22W from 1-33kΩ
Key specifications include operating temperature -55°C to +200°C, overload/over-voltage 10 times
rated power for 5 seconds, de-rating 80°C to 175°C linearly, tolerance (code) ± 1% (F), ± 5% (J), temperature coefficient 30ppm & 100ppm/°C as standard
ARCOL UK Ltd
New range of Hipot and Insulation Resistance testers
T
elonic Instruments have introduced a new range of Hipot (Flash) and Insulation Resistance testers manufactured by
Japan based Kikusui. Designated the TOS5300 the three models in the range are designed for use in Withstanding Voltage and Insulation Resistance testing to help ensure the safety of Electrical / Electronic components / equipment. Incorporating and innovative PWM amplifier that achieves high stability and has an input voltage regulation of.3%.
The series offer rise and fall time control of the test voltage and a stable output which is unaffected
by mains voltage variations, plus the ability to select 50 or 60Hz test frequency. Upper and lower current limits can be set within the range of 0.01mA to 110mA in AC mode and 0.01mA to 11mA in DC mode. AC test voltage is settable from 0.05kV to 5kV. D.C test voltages can be varied from 0 to 6kV. All models will operate from any global AC input voltages and frequencies; and are equipped with a USB interface. Also available for hire.
Telonic Instruments Ltd u 0118 9786911 u
www.telonic.co.uk
BL 550 from Knick: miniature set-point alarm relay with changeover output
T
he BL 550 set-point alarm relay from Knick's BasicLine program is a versatile and reliable solution for standard signal monitoring and control with an optimized price/performance ratio. The compact device comes in a 6 mm DIN rail housing with a potentiometer on the front for free adjustment of the switching thresholds. 0..20 mA, 4..20 mA, or 0..10 V input signal ranges, switching hysteresis, and delay are set via DIP switches. The changeover relay allows for the output to be used both with load and no-load currents.
All BasicLine devices provide galvanic three-port isolation, a standard feature of Knick products. The BL 550 set-point alarm relay is CE-compliant and UL-certified. Knick provides a three-year warranty on the device. Strictly concentrating on basic functions, leaving all extras aside, Knick has tailored BasicLine devices to mechanical engineering companies that need precise and reliable yet cost-optimized isolators for large-scale applications.
Knick Elektronische u +49 30 / 8 01 91 - 0 u
www.knick.de / ELECTRONICS
enter 826 enter 827
high-temperature industrial applications from 400 to 3,000 °C, for instance in steel production and processing,
R the chemical and petrochemical
industry, as well as heat treatment and power plants. Raynger® 3i Plus 1M and 2M models measure infrared radiation in the shortwave spectrum (1 µm and 1.6 µm) and provide high precision (+/- 0.5%, 1 °C). Thanks to the superior resolution of 250:1, critical plant parts and products can be reliably monitored from longer distances. For exact aiming, the measurement spot is highlighted with two laser beams. Moreover, even red hot objects can now be easily targeted by means of a new "Red Dot" scope sighting function (patent pending).
Raytek u +49 30 / 47 80 08 - 411 u
www.raytek.de
enter 828 ELECTRONICS | FEBRUARY 2015 31
Handheld infrared thermometer Raynger® 3i Plus
aytek presents a new handheld thermometer series for flexible temperature monitoring in
u 01872 277 431 u
www.arcolresistors.com enter 825
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48