Feature Machine Vision Getting results with automated inspectors
When it comes to quality control in manufacturing, the human eye can prove to be an unreliable detective. Automated vision systems are proving to be speedier and more reliable ‘inspectors’ - solving the trickiest of cases to save costs and improve product quality. Sensors and sensor solutions provider, SICK, explain
A
t a blow moulding plant in Essex, plastics manufacturer Logoplaste is showing how machine vision can make elimi- nating rejects easier. Working with SICK UK, the number of defective two litre milk containers delivered to one of its customers (a major UK dairy products company), has reduced to nearly zero.
By replacing manual batch quality checking with SICK Inspector I20 vision cameras, the production team has almost completely eliminated the number of problem bottles that used to slip through the net and end up with the customer. Not only has this improved Logoplaste’s relationship with the customer, it has saved on the potential for punitive fines. Logoplaste is a major industrial group which manufactures rigid plas- tic bottles in-house in 62 factories located in 18 countries worldwide serving the food and beverage, per- sonal care, household care and oil and lubricants sectors.
A close eye on production At its plant in Hatfield Peverel, the two 500m lines produce 6,000 milk bottles an hour each from HDPE resin with an added white pigment. Two SICK Inspector I20 vision cameras are posi- tioned on each line to inspect every single moulded container at full line speed, replacing the human batch inspection rate of just 14 units per hour. “SICK were very supportive and helped us to run a two day trial which demonstrated how effective the Inspector I20 would be for this appli- cation,” explained Logoplaste plant manager Jon Hart. “We were then able to build the mounting frames, install the cameras and get the system up and running within two weeks. “We found the SICK system was very easy to set-up, calibrate and commis- sion. The Inspector I20 also offered a degree of precision which enabled us to search for patterns that other cameras might have found difficult to detect. “The Inspector I20 vision cameras are positioned at close range to scan the top and handle of each container. We have been able to move from 10-15 related customer complaints per year down to only one since installation - almost a 100% reduction. “Very quickly we had total quality
Machine Vision OCTOBER 2013 removed prior to filling.
“Sometimes the moil and the handle may be damaged during the de-flashing process. If the moil is dented or deformed, it may affect the clean removal of the moils. If there are pieces of flashing on the moil or handle, they could possibly enter the bottle at this point. Holes, tears or weak points on faulty handles will cause the loss of
control on each line, removing the need for human inspection with all the prob- lems of error, fatigue and capacity. Whilst our man-power levels have remained unchanged, we have been able to remove five minutes per hour from QC checks.
“Most importantly, we know instantly if there are problems and we can rectify plant faults in real time. With the previous batch inspection there was a time lag and we could only work back to faults retrospectively.”
Blow moulding
The blow moulded bottles are con- veyed to the customer’s plant as asep- tic fully enclosed containers. The ring of material at the neck - known as the moil - is removed later in the cus- tomer’s process prior to filling. During the moulding process, flash- ings occur at the moil and the handle. Automatic trimming removes the flashings before the containers are conveyed to the customer.
“During trimming, it is possible for the small pieces of flashing to be left attached to the moil or entire handle slugs left in place,” commented Trevor Seabrook, production manager at Logoplaste. “These can be a problem on the filling line, where the moil is
Above: two SICK Inspector I20 vision cameras are
positioned on each line to inspect every single
moulded container at full line speed
Left: by replacing manual batch quality checking with SICK Inspector I20 vision cameras, the production team at Logoplaste has almost completely eliminated the number of problem bottles that used to slip through the net and end up with the customer
sterility, or could leak after filling. “It is in our interest to eliminate any problems as soon as they are detected in order to supply our cus- tomer with zero quality issues.” Each line has one SICK Inspector I20 scanning the container necks and one scanning the section of the handle where untrimmed flashings remain. Set at 40mm from the target, the Inspector I20 compares each scan against a pre-programmed image. If a fault is identified, an alarm is triggered and the faulty unit can be removed from the line before palletis- ing. Faulty containers are recycled. While the Inspector I20 cameras may be controlled via its integral digital IO or PC interface, Logoplaste took the deci- sion to add an Inspector Viewer HMI for each line. As well as easy control and overview, the Viewer enables the collec- tion of data and trends, as well as images, and improves the versatility of the quality control system.
“The Inspector I20 vision cameras have now been running for 18 months without issues. We are going to recom- mend this approach for similar lines at a company technical forum in the near future,” added Seabrook.
SICK
www.sick.com T: 01727 831 121
Enter 231 S9
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72