This page contains a Flash digital edition of a book.
To order call +44 (0)845 089 4060 or visit www.scafftag.co.uk


The World Leading Scaffold Status Tagging System Scafftag® SCAFFTAG® ERECTION & INSPECTION RECORD


Location Ref. No.


LOAD CLASS 1 UDL 0.75 Kn/M 75 Kg/m


2


UDL 1.50 Kn/M 150 Kg/m


LOAD CLASS 2 LOAD CLASS 3


2 2


UDL 2.00 Kn/M 200 Kg/m


2 2


STRUCTURE TO BE USED FOR 2


2 300 Kg/m2


LOAD CLASS 5 LOAD CLASS 6


UDL 4.50 Kn/M 450 Kg/m


2 2


UDL 6.00 Kn/M 600 Kg/m


Competent Person Date Time Signature 2 2


If last inspection exceeds 7 days remove insert and inform supervisor


LOAD CLASS 4 UDL 3.00 Kn/M


WARNING


UNLAWFUL REMOVAL OR INTERFERENCE WITH THIS SIGN COULD MAKE YOU LIABLE TO PROSECUTION AND FINES


TO BE COMPLETED BY SUPERVISOR REQUESTED BY:


BUILT BY: DATE ERECTED: SIGNATURE


TO BE COMPLETED BY INSPECTOR


BEFORE BEING TAKEN INTO USE FOR THE FIRST TIME


INSPECTORS NAME & SIGNATURE DATE & TIME DECOMMISSIONED DATE


© Brady Corp Ltd 2011 Tel: +44(0)845 089 4050 www.scafftag.com Ref. STH


ANY QUERIES REGARDING THIS STRUCTURE SHOULD BE MADE BY CONTACTING.


CAUTION


THE FOLLOWING HAZARDS SHOULD BE NOTED


NAME: TEL:


© Brady Corp Ltd 2011 | Tel. +44(0)845 089 4050 www.scafftag.com | Ref. STSI


TG:20 Inserts


Alternative inserts are available which use colour-coding and pictorial images indicating instantly the maximum load recommendations for the scaffold in question. These are particularly useful for sites where varying maximum loadings are in place, and for sites where English is not everybody’s first language.


Scafftag® MK1 (for Tube & Clip Scaffolding)


Helps you manage and communicate the changing status of your equipment in terms of health and safety, maintenance and identity to improve compliance.


CAUTION


THE FOLLOWING HAZARDS SHOULD BE NOTED


CAUTION


THE FOLLOWING HAZARDS SHOULD BE NOTED


CAUTION


THE FOLLOWING HAZARDS SHOULD BE NOTED


CAUTION


THE FOLLOWING HAZARDS SHOULD BE NOTED


CAUTION


THE FOLLOWING HAZARDS SHOULD BE NOTED


SCAFFTAG®


HEAVY DUTY USE ONLY


100 Kg


per m2 2.5 kN/m2


51.1 lbs / sq. foot


LOCATION: REF No.:


DATE ERECTED:


If last inspection exceeds 7 days remove insert and inform supervisor


DATEDATE TIME SIGNATURE


LOCATION: REF No.:


DATE ERECTED:


If last inspection exceeds 7 days remove insert and inform supervisor


DATEDATE TIME SIGNATURE  2 kN/m2 SCAFFTAG®


GENERAL PURPOSE USE ONLY


50 Kg per m2 42lbs / sq. foot = 200 Kg/m2


LOCATION: REF No.:


DATE ERECTED:


If last inspection exceeds 7 days remove insert and inform supervisor


DATEDATE TIME SIGNATURE  SCAFFTAG®


LIGHT DUTY USE ONLY


31.5 lbs / sq. foot 50 Kg


per m2 1.5 kN/m2


SCAFFTAG®


VERY LIGHT DUTY USE ONLY


 per m2


.75 kN / m2 15lbs / sq. foot





FOR INSPECTION PURPOSES ONLY ONE MAN - NO LOADS


LOCATION: REF No.:


DATE ERECTED:


If last inspection exceeds 7 days remove insert and inform supervisor


DATEDATE TIME SIGNATURE SCAFFTAG® SPECIAL PURPOSE CONSTRUCTED FOR SPECIAL USE


USE OR LIMITATIONS: LOADING OR RESTRICTIONS:


LOCATION: REF No.:


DATE ERECTED:


If last inspection exceeds 7 days remove insert and inform supervisor


DATEDATE TIME SIGNATURE


ALUMINIUM TOWER ERECTION & INSPECTION RECORD THIS TOWER IS FOR THE SOLE USE OF


WARNING AUTHORISED PERSONNEL ONLY THIS TOWER STRUCTURE TO BE USED FOR:-


VERY LIGHT DUTY USE ONLY


= 2 MEN + LIGHT TOOLS + LIGHT WT MATERIALS PER PLATFORM LEVEL


TOWER REF NO: 1st LOCATION:


1st LOCATION WILL BE MOVE Ref. 1


DATE ERECTED: ERECTED BY: SUPERVISOR:


DO NOT USE


TOWER


©Copyright Brady Corp Ltd 2011 Tel: +44(0)845 089 4050 www.scafftag.com Ref. STH 368


THIS TOWER TO BE USED BY COMPETENT PERSONS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS.


Inspection should be carried out after erection or modification and not exceed a 7 day period if still in use


MOVE Ref. DATE TIME SIGNATURE DETAILS OF TOWER


INTERNAL MOBILE


STABILIZERS FITTED TIED IN


LADDER ACCESS STAIR ACCESS


EXTERNAL STATIC


MAX HEIGHT OF PLATFORM:


Y Y Y Y


M


N N N N


EVACUATE ALL PERSONS & MATERIALS BEFORE MOVING TOWER. MOVE TOWER MANUALLY ONLY AT GROUND LEVEL.


ANY QUERIES REGARDING THIS STRUCTURE SHOULD BE MADE BY CONTACTING.


NAME: TEL:


© Copyright Brady Corp Ltd 2011


TEL +44(0)845 089 4050 Re-Order Ref: STSI 368 www.scafftag.com


UNLAWFUL REMOVAL OR INTERFERENCEWITH THIS SIGN COULD MAKE YOU LIABLE TO PROSECUTION AND FINES


TOWER MOVEMENTS:-


MOVE Ref. 2.


3. 4. 5.


6. 7.


DATE LOCATION


Towertag


The Towertag system uses our unique holder and insert system to ensure the latest status is instantly visible at the point of use. Towertag is specifically designed to show locations and move references.


Scaffold Inspectors Prohibition Insert


Scaffold inspector’s prohibition insert to help prevent working at height hazards and efficiently manage inspection procedures. Designed to operate alongside Scafftag holder.


Scafftag®


Blue Book for Scaffolding


Scafftag’s Blue Book for Scaffolding collects together all the elements required to manage your scaffolding onsite in one protective binder. Contains legislative and risk assessment guidance, inspection reports etc.


®


®


STRUCTURAL TIE DO NOT


REMOVE THIS TIE OR TAG


REMOVED BY AUTHORISED PERSONS ONLY IF REQUIRED - PLEASE CONTACT:


Name: Tel No:


THE ANCHOR ATTACHED TO THIS TIE HAS BEEN TESTED Tie No:


Lift No: Test Date: Test Load Applied: Required Tensile Load:


© Copyright Brady Corp Ltd 2011 | Tel: +44(0)845 089 4050 www.scafftag.com | Ref. MISC 189


KN KN


DO NOT


REMOVE SCAFFOLD TIE


INTERFERENCE WITH THIS SIGN COULD MAKE YOU LIABLE TO PROSECUTION AND FINES


© Copyright Brady Corp Ltd 2011 | Tel: +44(0)845 089 4050 www.scafftag.com | Ref. MISC 190


WARNING UNLAWFUL REMOVAL OR


Structural Tie TEST Tag


A strucutral tie tag which records the specific tie Test Date/Test Load Applied/Required Tensile Load and a unique reference number for ongoing monitoring.


Structural Tie WARNING Tag


A prohibition only tag for those ties not being tested. Helps you to comply with legistlative requirements.


Revolutionise Your Scaffolding Management Processes


Produce reports for structures that have passed, failed, due inspection, been commissioned and decommissioned by date


Track and control the request, hand-over, inspeciton and decommission process, identify structures and their location


Meet legislative requirements by providing a clear, visible and auditable trail of inspections, endorsements, recommendations and actions


Improve planning and increase accuracy Reduce paperwork and reporting time


To order call +44 (0)845 089 4060 or visit www.scafftag.co.uk


Order code: MISC 189


Order code: STSH 368 SPLIT A


Order code: STSH


Order code: MISC 190


Order code: STSIP


Order code: SIB


Order code: STSI 479 - 483


NEW


NEW


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88