INTERCONNECTION FEATURE


CHOOSING AN EXTREME TEMPERATURE CONNECTOR How picking the right connector first time can make the difference


When designing industrial equipment, the operating temperature of the product is often at the top of the list for design engineers. This makes sense, after all, you don’t want to keep replacing failed equipment. However, while engineers give a lot of thought to heat in the equipment itself, the performance of the connectors and cables that join different devices is often overlooked. Here, Jonathan Parry, senior vice president of global operations and European managing director at PEI-Genesis, explores what to consider when choosing an extreme temperature connector


environments, such as on trains and boat engine rooms, where low-smoke-zero- halogen (LSZH) plastics are often used to avoid the build-up of dangerous fumes or explosive atmospheres created by burning or outgassing plastics. An example of this style of connector is


the PEI-Genesis supplied VEAM CIR from ITT, which has been specifically designed for extreme temperatures. This connector uses specialised LSZH plastic inserts and a variety of enclosure materials, which gives it the capability to meet ISO 834-1 fire standards, where the connectors are exposed to temperatures as high as 8000


C. Sliding back down the scale, we reach C


hoosing a connector, for most can be as simple as deciding between a one


or two metre USB cable, but we still get very annoyed when the connection starts to become unreliable. For the engineer the choice is far more


complex, and the consequences far more serious than having to wiggle the connector until it works. A dropped connection could mean losing control of heavy autonomous equipment, a stopped machine and jammed-up production line, or many other detrimental effects that are best avoided. While the working equipment in


industrial settings is often well monitored by governing software and vigilant engineers, it’s often the case that the connectors are overlooked, despite them being just as crucial as any piece of line equipment. Heat, particularly in the extreme, is a


factor that engineers constantly tackle. Heat is a natural consequence of many industrial processes, and many more still involve heat directly in the process, such as smelting and other metalworks. Most equipment uses active cooling to


control this heat, such as ventilating fans, cooling lubricant sprays and water- cooling. For the connectors this is often


not possible, which makes the choice of connector in the first instance very important. When dealing with hot environments


it’s tempting to simply pick a connector with a metallic housing, such as steel or aluminium, because these metals


typically don’t melt before a few-hundred 0


C. Doing this overlooks major problems,


however. For instance, the connector enclosure might easily withstand the high temperatures in question, but inside the enclosure can act as a heatsink because heat isn’t actively wicked away. Many connectors, such as common USB


and serial ports, rely on plastic inserts to house the contacts, while other connectors may also enclose electronic components such as resistors, ballasts and rectifying circuits, which may be susceptible to temperatures lower than the enclosure material. Even if temperatures don’t actually melt


or scorch these plastic components, procedural stress caused by the high temperatures, as well as the effects of thermal expansion and contraction can cause connectors to fail well before their expected lifecycle. Particular attention must be paid to connectors in hot and enclosed


/ ELECTRONICS Figure 2:


Jonathan Parry, senior vice president of global operations and European managing director at PEI-Genesis


Figure 1:


PEI-Genesis’ cables and connectors manufacturing


the arena of cold-temperature connectors. This initially seems far easier to solve than heat, primarily because most industrial processes are exothermic. Therefore, the cold temperatures that


connectors are exposed to are often natural, with connectors being continually exposed to the elements. These cold environments often preclude the use of many plastic and rubber enclosed connectors because they can freeze and crack, creating openings for moisture to wreak havoc. With the correct choice of connector


configuration and materials, however, this style is perfectly possible. The PEI- Genesis supplied Sure-Seal Connectors range is one such low-temperature capable connector. These connectors are enclosed in a PVC nitrile plastic which remains flexible, supple and resistant to cracking down to temperatures as low as -400


C. Many industries treat connectors as a


quick, one-time decision taken during integration, despite the consequences of failure perpetually bringing the problem back onto the agenda. With some more consideration, though, it’s possible for that decision to be truly long-lasting.


PEI-Genesis www.peigenesis.com


ELECTRONICS | OCTOBER 2020 21


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46