search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
Test & measurement Y


okogawa Test & Measurement Corporation announces the release of its DLM3000HD series high-definition oscilloscopes supported by new IS8002CDV Classic Data Viewer (CDV) software. The compact and


lightweight multi-channel DLM3000HD meets market demand for high-precision, high-speed measurement of complex digital waveforms during inverter/motor development and testing. With a lineup spanning 500 MHz and 350 MHz frequency bandwidth models, the combination of proprietary low-noise detection and high resolution allows technicians to perform studies in minute detail, faster than ever before. The new IS8002CDV software further supports expediency with its rapid response times, swift analysis of measurement data, and advanced algorithms.


DEVELOPMENT BACKGROUND Building on the existing DLM3000 mixed-signal oscilloscope series launched in 2018, Yokogawa applied its 100+ years of expertise and innovation in measuring instrument technology to develop the DLM3000HD. The product stems from requests made by customers for a lightweight, compact oscilloscope with higher precision and rapid start-up speed that supports the ongoing requirement for more energy- efficient and sustainable motors and inverters. Adopting the DLM3000HD to capture highly accurate voltage and current waveforms with high sample rates addresses the capabilities of electric motors and drives to ensure efficiency in transportation sector applications, for example. Another development driver is next-generation power devices deploying silicon-carbide (SiC) technology, which can switch on and off in a few nanoseconds. Oscilloscopes offering bandwidths of 350 MHz or greater are necessary to capture the fast rising and falling edges of the transient (high-intensity voltage spike during switching). Thanks to its multi-channel measurement, wide bandwidth capabilities and vastly improved vertical axis resolution compared with the existing-generation oscilloscope, the DLM3000HD series steps up to the challenge of performing high-precision parameter measurements, statistical analysis, and real-time mathematical functions.


MAIN FEATURES


In comparison with the existing DLM3000, resolution some 16 times greater (12 bit) in the vertical axis captures waveform overshoot and ringing for more accurate observation of tiny changes in high-speed signals. A long 1 Gpoint memory (double the 0.5 Gpoint memory of the DLM3000) supports the development and evaluation of next-generation inverter devices by recording multiple channels simultaneously, greatly increasing work efficiency. Engineers can make accurate observations of subtle changes in measurement target signals over a long period of time (even at high sample rates up to 2.5 GS/s), confirm signal waveforms, and detect signals causing unexpected anomalies.


76


HIGH-DEFINITION OSCILLOSCOPES AND DATA VIEWER SOFTWARE


Another unique feature of the DLM3000HD series is the pioneering auto set-up function for in-vehicle serial bus development and evaluation, a capability that is also possible during post data acquisition analysis. This time- saving function, which automatically configures the optimal bit rate and threshold level, accelerates the delivery of secure, reliable measurement results in the automotive industry. Users can take advantage of 4-channel synchronous measurement with the DLM3000HD, while the optional dual-unit synchronous measurement (DLMsync) function facilitates a unified system of 8 channels at the touch of a button via the connection of two units. In addition, the DLM3000HD supports time synchronisation with power analyzers and other waveform measuring devices, providing


time-correlated measurements.


High noise immunity allows operation even in the harsh environmental conditions often prevalent in development and testing areas, meaning the touch panel is far less likely to malfunction. It is possible to disable the touch panel and use only the buttons if absolutely necessary. With its updated UI, IS8002CDV software offers easy remote control without the need for any programming. There is no learning curve thanks to emulation of the instrument on the PC, allowing operation as normal. The offline analysis of files also allows engineers and researchers to use the instrument for other measurement tasks, increasing its utilisation.


Yokogawa Test&Measurement tmi.yokogawa.com


September 2024 Instrumentation Monthly


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100