Test & measurement
Fig. 3: The VNA firmware from Rohde & Schwarz automatically detects the R&S OSP switch as a port extension. In this example the 4-port VNA behaves like an 24-port VNA. This feature is adopted by R&S ZNrun Cable Test Client.
differential signal paths. IEEE 802.3 cable verification requires testing the transmission (THRU) of each lane and crosstalk for all neighboring lanes: near-end crosstalk (NEXT) and far-end crosstalk (FEXT). For more information, see [1].
When higher data rates are needed, the number of lanes in a cable also increases. Manual testing is repetitive, time consuming and error prone. The main cause is the increased number of reconnections and measurements with a 4-port vector network analyzer (VNA). Testing can take up to several days for each cable, such as eight-lane QSPF-DD/OSFP- cables, where users must perform 256 manual measurements and cable reconnections. A further challenge is post-processing data
collected in line with the standard to determine whether a cable passes or fails. The ever increasing complexity and variety of the metrics in various standard specifications make for a heavy workload. IEEE 802.3 defines the channel operation margin (COM) and effective return loss (ERL) as metrics. Excursion metrics for integrated return loss (iRL) and NEXT/FEXT component-contributed integrated crosstalk noise (ccICN) have been introduced for PCIe.
TIME EFFICIENT TURN-KEY SOLUTION Rohde & Schwarz has developed an automated test solution for high-speed cables to relieve test engineers of time consuming and repetitive tasks. The solution combines the
precision and performance of an R&S ZNB vector network analyzer with the R&S OSP open switch and control platform and the R&S ZNrun VNA software suite for faster, easier and more reliable measurements. The R&S ZNrun Cable Test Client and newly introduced R&S ZNrun-K4xx compliance test automation options make for a straightforward test procedure with three simple steps: set up, calibrate and measure. Each step is optimized to minimize calibration and measurement times. The R&S ZNrun Cable Test Client configures switches, performs all required measurement steps and postprocesses all measurement data in line with the COM, ERL, ccICN, iRL and other standard specifications. The solution
Fig. 4: Measurement results for insertion loss as displayed in the automatically generated report Instrumentation Monthly October 2024
Continued on page 24... 23
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96