ADVERTISEMENT FEATURE  Cover story


City Technology’s Catalytic Bead Sensors now reapproved for use in Zone 0 applications


Shawcity is pleased to announce that City Technology has reapproved its 4P catalytic bead and MICROpeLTM pellistor sensors listed below to the updated standard, thereby extending their use in most hazardous locations


and T4 and T5 classes for the MICROpeL 75 range. Ultimately, this means that instrument manufacturers who are using our catalytic bead sensors can re-certify their existing products so they can also be used in Zone 0. The BS EN 60079-1:2014 is the UK implementation of EN 60079-1:2014, the European standard “Equipment for explosive atmospheres”. Part 1: Equipment protected by flameproof enclosures "d" has been updated to the 2014 edition which includes an option for portable products to be approved to "da" for use in Zone 0 applications.


T


he ATEX Category 1 certification (Ex da) is available with T5 and T6 temperature classes for the 4P range


4P90, 4P90C, 4P90M, MICROpeL75, MICROpeL75C, MICROpeL75M.


LEAD-FREE 4OXLL AND 5OXLL OXYGEN SENSORS We offer two long-life oxygen sensor formats which are designed to work in an analyser for seven years, the entire life of the instrument. Available in 4 and 5 series formats, they offer an enhanced response time in extreme conditions. Based on electrochemical pump technology, the design avoids using a consumable anode (lead), the life-limiting component of many sensors. This technology significantly reduces the cost of ownership and the occurrence of field failure, helping manufacturers to reduce their servicing costs as well as achieving ROHS compliance. In terms of performance, the lead-free


City Technology’s catalytic bead sensors offer a more stable and flexible solution for combustible gas detection. Built to better resist toxic environments, they deliver faster response and recovery times. The sensors come with different filter options along with flameproof housing, while the range also has enhanced resistance to shock and vibration. Our Zone 0 Approved Sensors are as follows: 4P50, 4P50C, 4P50M, 4P75, 4P75C, 4P75M,


8


sensors offer fast response and recovery times with T90 <15sec, as well as an O2 offset <0.3%. They are also highly stable, with a <5% signal loss over lifetime. With over 300 high performance sensor products detecting over 30 common and exotic gases, Shawcity’s range includes 1, 3, 4, 5 and 7 Series, MICROcel, MICROpel and Sensoric sensors. Our high-performance sensors are used across various applications and we work closely with businesses and organisations operating in fields as diverse as medical, metal processing, chemical, automotive, agriculture, pharmaceutical, textiles, water & waste water treatment, mining, pulp & paper processing, gas detection/monitoring manufacturers, petrochemical, utilities and R&D institutes, including leading universities. Our range offers detection for the following


gases: Acrylonitrile, Ammonia, Arsine, Carbon Dioxide, Carbon Monoxide, Chlorine, Chlorine


Dioxide, Combustible Gases, Diborane, Ethylene Oxide, Exhaust Gases, Fluorine, General Air Quality, Hydrazine, Hydides, Hydrogen, Hydrogen Chloride, Hydrogen Cyanide, Hydrogen Fluoride, Hydrogen Selenide, Hydrogen Sulphine, Mercaptan, Methane, Nitric Oxide, Nitrogen Dioxide, Oxygen, Ozone, Phosgene, Phosphine, Silane, Sulphur Dioxide, Tetrahydrothiophene and more.


Shawcity’s customer base stretches across the entire EMEA region and we cater for companies of all sizes and specialisms. We understand the demands of the industry and offer: - - -


Advice for R&D and start-up projects One-offs and sample sensor orders Account support for quantity breaks


- A range of stock available for immediate dispatch.


For more information about the range of


sensors available to order and quantity price breaks please visit: www.shawcity.co.uk/sensorrange or contact us by emailing solutions@shawcity.co.uk or calling 01367 899420.


Shawcity www.shawcity.co.uk September 2020 Instrumentation Monthly


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78