• • • TEST & MEASUREMENT • • •
Measuring beyond the 50th harmonic: What to consider when
choosing a power quality metre By John Mitchell, Global Sales & Marketing Director, CP Automation
but most power quality measurement and mitigation devices are yet to catch up. Because most metering devices still work to the old standard of 2.5 kHz (50th order), these cannot provide a complete picture of the spectrum, leaving engineers in the dark. So, how can operators ensure they choose the right metre? John Mitchell, Global Sales & Marketing Director at CP Automation, explores.
T
Anomalies such as sags, swells and harmonics are an ongoing threat in electrical circuits and a common cause of equipment downtime. Power quality metres strategically sample the AC voltage at different points and track slowly changing variations in the electrical waveform. Using this
he Engineering Recommendation G5/5 has extended the values for planning and compatibility levels to the 100th
information, operators can root out any issues before they cause lasting damage.
order (5 kHZ),
When it comes to electrical matters, the need for rapid detection is clear: transients can appear, cause damage and disappear in a few millionths of a second. Similarly, a voltage spike typically lasts one to 30 microseconds and can reach over 1,000 volts.
Therefore, acting quickly to install a measurement device is critical, but so is choosing a metre that tells you what you need to know.
What can it measure? Usually, the dashboard warning lights in your car will tell you if your oil pressure has dropped, if the fuel level is low, or if there’s an issue with your steering lock. However, they won’t tell you if your cambelt is worn, and you might not find out
something’s wrong until it’s too late. The point is that you don’t know what you don’t know – and the new Engineering Recommendation has opened a blind spot by extending the values for measurement. Visibility of issues across the frequency spectrum is critical, so try to select a power quality metre that captures as many parameters as possible. Usually, low-level power and energy metres will measure things like voltage, current and maybe power factor but not much else. Even if you purchase a slightly more expensive metre that provides basic harmonic data and frequency values, it’s unlikely that this will measure beyond the 50th
harmonic, leaving operators back at square one.
Class A metres and analysers can facilitate more advanced troubleshooting of complex electrical systems, and many will measure up to the 100th harmonic. These are the gold standard of power quality metres, and operators will need their accuracy to inform discussions with the distribution network operator (DNO).
Fixed or portable?
There’s also the matter of duration and how long operators plan to monitor the system. If a circuit board randomly fails or alarms trip, installing portable metres can help engineers perform spot checks by gaining insights at different locations. For example, these metres could detect any changes in low-voltage, medium-power systems, such as spikes in energy consumption. With G5-5 now in place, blind spots in the frequency spectrum are an issue for portable metres because most will only measure up to the 50th harmonic. Some fixed metres and analysers, like the PQube3 and Janitza’s UMG range, can not only measure beyond this point but also facilitate root-cause analysis by mapping long-term trends. Operators can strategically install fixed metres at different locations and record data over several weeks, or even months. For example, with multiple fixed metres in place, a power quality engineer can pinpoint a time when harmonics were detected in the system, and when this caused a spike in energy consumption.
The latest engineering recommendations present a challenge for equipment operators because the goalposts for power quality measurement have shifted. However, this also grants an opportunity to improve uptime by detecting a wider range of issues early on. To help you choose the right power quality measurement and mitigation solution for your application, visit the CP Automation website.
32 ELECTRICAL ENGINEERING • MARCH 2025
electricalengineeringmagazine.co.uk
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54