Emergency Lighting:
Navigating Upcoming Changes To BS Standards
A legal requirement in all public and high occupancy buildings, emergency lighting plays a critical role in safeguarding lives during emergency situations. With changes to the regulatory landscape afoot, we spoke to Chris Anderson, Technical Manager at Ansell Lighting, who provided an overview of the new recommendations.
With emergency lighting sat firmly at the heart of a building’s health and safety requirements, understanding, and complying with changing regulations is a key factor in the role of many facilities managers.
Crucial for ensuring the safety of building occupants, emergency lighting plays a critical role in facilitating smooth evacuation during unexpected or hazardous situations. It can also help to prevent panic, enhance security, aid emergency services and in the event of a power failure, it can provide illumination to ensure a proper shutdown procedure is carried out, and to permit operations concerned with safety measures.
Stipulated under Approved Document B of Building Regulations for use in England and in the same for Wales, as well as within the Building Standards for use in Scotland, emergency lighting is a legal requirement in all public, commercial, and high occupancy residential buildings.
There are also several British Standards that apply to emergency lighting advising on all areas of best practice. Standards BS EN 1838:2013 and BS EN 50172:2004 are currently going through the process of being re-written and will mean that changes to existing installations and their maintenance practises are required in buildings across the country. Publication of the new codes are set for later this year.
BS EN 1838:2013 stipulates the illumination to be provided by emergency lighting (including illuminance, duration & colour). The standard covers both temporary and permanently installed electrically powered emergency lighting and applies to self- contained luminaires with integral batteries, centrally powered luminaires, and to centrally generator powered luminaires.
38 fmuk
One of the main updates to EN1838 concerns local area safety lighting which protect occupants who are allowed to remain in a building in the event of a supply failure (based on a safety risk assessment).
The standard stipulates that the maintained illuminance of local area safety lighting shall be based on risk assessment but shall be at least 1Lux on escape routes up to 2m in width and 0.5Lux in open areas with a floor area greater than 60m (excluding a border of 0.5m around the perimeter).
The British Standard, EN1838 also stipulates that the minimum duration the local area safety lighting should last is 1 hour and that escape route lighting from the area of safety to the final exit shall have a duration equal to or greater than the local area safety lighting.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44