| New uses for fossil assets
recently, in Slovenia, at the currently fully operational Velenje lignite mine. Systems such as that being developed by Gravitricity, storing surplus power, have the potential to provide instant power at scale, eventually using numerous distributed installations at former mine shafts, offering an alternative to batteries and other quick response storage technologies.
Mixed generation power stations, batteries, hydrogen, and salt storage
Figure 2. Heat pump system that can use warm mine water to provide heating (Image Bigstock, redrawn by ICSC)
partially reproduced in a mine. Similar concepts use compressed air storage built into a coal mine that avoid the need for large pressure vessels. The storage of hydrogen could also be in vessels located ‘in shaft’ and for enhanced safety, underground storage means a larger volume and pressure, potentially enabling hydrogen fuelling infrastructure.
At depth, water in mines is warmer, a geothermal energy source of increasing interest for district heating schemes; heat pumps can provide a hot water supply. The water in mines tends to remain at constant temperature regardless of the season and can be a heat source or be used for cooling. There is particular interest in closed systems where the temperature of the reservoir can be raised during summer months and, absorbing waste heat, store thermal energy for the winter. Mine water systems can replace district heating schemes previously supplied by coal stations that strived for high thermal efficiency.
Heat pump systems (see Figure 2) need about a quarter of the electricity required by a comparable direct electric heating installation and are competitive with gas boilers. Mine water is a more reliable heat source than air, and the limitation of modest outlet temperature in original designs has recently been overcome with the introduction of new heat pump fluids possessing higher vaporisation energies. An example is propane (R290), which allows higher hot water temperatures, negating the need to change domestic radiator installations. Deep mine shafts are suitable for a rapid response gravitational energy system. A novel technology, raising weights during surplus power
Right: Figure 3. Four synchronised winch/ motor-generators can handle 500 t weights in a 700 m deep mine shaft (Image courtesy Gravitricity, source https://jtp.
app.swapcard.com/event/just-transition- platform-conference-coal-regions-in-transition- and-carbon-intensive-regions/planning/ UGxhbm5pbmdfMTAwMDg3OA==, European Commission 6th Just Transition Platform Conference – coal regions in transition. Brussels, Belgium, EU, 10 pp (2022))
www.modernpowersystems.com | April 2024 | 13
periods and then lowering them into a shaft, can generate power during shortfalls and store power when in excess, using a combination of winches (mine hoists) and motor-generators, as depicted in Figure 3.
Following successful pilot trials, Gravitricity in partnership with ABB, a mine hoist specialist, is building two 2 MW/4 MWh commercial plants, one at a former copper mine in Finland and a similar system at the 700 m deep Darkov coal mine in Czechia. The technology is also under consideration for mine site applications in Germany and, most
Renewable generation combined with storage and a fuelled power plant can supply dispatchable power more reliably than solar and wind alone. In Europe, a generating hub would comprise wind and solar farms, hydrogen electrolysis and battery storage together with a former coal power plant, possibly refuelled with biomass or natural gas. Hydrogen is seen as a desirable fuel to replace fossil fuels in industry, with electrolytic hydrogen installations planned across Europe and the USA. Ideally these hubs would operate to maximise the use of solar and wind power but also allow fuelled stations to operate closer to optimal efficiency, maximising power/CO2
, while
storing surplus power as hydrogen. In Germany, where development of a series of energy hubs is in progress, the need for hydrogen storage can be reduced by feeding straight into existing pipeline networks, avoiding new leakage points.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43