Reliable heating controls built for the long-term demands of social housing


F


or housing associations and local authorities, maintaining existing heating systems can be a tricky balancing act.


Budgets remain are ever-tightening, housing stock is continuing to age, and expectations around energy effi ciency and tenant comfort are only increasing. As a result, selecting heating controls that are robust, easy to maintain and designed to deliver reliable performance over many years has never been more important. Manufactured in the UK, Drayton has spent decades developing heating control solutions that meet the practical needs of installers, maintenance teams and housing providers alike. Its range of motorised valves and thermostatic radiator valves (TRVs) is designed to simplify servicing, minimise disruption and help ensure heating systems continue performing effi ciently throughout their lifespan.


MAKING MAINTENANCE SIMPLER Within social housing, planned maintenance and component replacement are far more common than complete heating system upgrades. That’s why ease of installation and servicing plays such a vital role in reducing both costs and downtime. Drayton’s motorised valves are available in both 2-port and 3-port versions, with 22mm and 28mm options to suit the heating systems that are most commonly installed across UK housing stock. Designed around industry-standard dimensions and wiring confi gurations, they enable straightforward replacement of existing valves, allowing engineers to complete work effi ciently while limiting disruption for residents. Every valve is also individually tested before


leaving the production line, ensuring consistent quality and dependable performance in the fi eld. This commitment to manufacturing excellence has helped Drayton establish a strong reputation among installers, refl ected in its excellent customer satisfaction ratings. Future maintenance is equally


straightforward thanks to snap-on actuator technology, which allows actuators to be replaced without draining the entire heating system. This not only reduces labour time but also helps keep properties heated while maintenance is carried out, benefi ting both landlords and tenants.


IMPROVING COMFORT WHILE SUPPORTING ENERGY EFFICIENCY Giving residents greater control over their heating is one of the simplest ways to improve comfort while reducing unnecessary energy consumption. Thermostatic radiator valves enable individual room temperature control, allowing occupants to heat spaces according to how they are used. Drayton’s RT212 and RT414 valves have been developed with the needs of social housing front of mind. Fully compliant with BS EN 215, both models use liquid sensing technology to deliver accurate temperature regulation, helping maintain consistent comfort levels throughout the home. Range-limiting functionality also allows


landlords to set minimum and maximum operating temperatures where required, preventing excessive heating while ensuring properties remain comfortable and safe for occupants. Where additional durability is needed, the


RT414 off ers further benefi ts through non-stick internal components that help reduce limescale build-up. By lowering the risk of valves sticking after prolonged periods of inactivity, housing providers can reduce maintenance call-outs and extend product life.


A TRUSTED SOLUTION WITH PROVEN EFFICIENCY For more than three decades, Drayton’s TRV4 has been a familiar product for heating engineers across the UK. Available in Classic and White – both of which have a Class 1 rating from


the European Valve Manufacturers Association – alongside Chrome and Anthracite fi nishes, it combines reliable performance with one of the highest effi ciency ratings available, achieving a Class 1 rating from the European Valve Manufacturers Association. Designed for long-term reliability, the


TRV4 incorporates non-stick internals, double gland seals to minimise the potential for leaks and a top-seal arrangement that enables servicing without draining the heating system, making ongoing maintenance faster and more cost-eff ective.


PERMANENT BALANCING FOR BETTER SYSTEM PERFORMANCE Available on selected TRV4 and RT414 models, Drayton’s permanent auto-balancing technology helps heating systems operate more effi ciently by automatically regulating water fl ow to individual radiators. Unlike manual balancing, which can drift


over time, the technology continually maintains optimum fl ow rates throughout the life of the system. The result is more even heat distribution, fewer hot and cold spots, improved boiler performance and reduced commissioning time. Independent testing has shown average


energy savings of 8.8%, helping housing providers reduce running costs while improving comfort for residents and minimising future maintenance requirements. Supported by UK manufacturing and


technical expertise from its Plymouth headquarters, Drayton continues to provide housing associations and local authorities with dependable heating control solutions designed to simplify maintenance, improve effi ciency and deliver reliable performance for years to come. To fi nd out more about Drayton’s range of


heating controls, please visit the website. 0333 6000 622 www.draytoncontrols.co.uk


WWW.HBDONLINE.CO.UK


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76