Free Light Chain Assays Freelite Serum Free Light Chain Assays
Ranges quoted are for initial recommended sample dilution. An extended range is possible for all kits using automatic instrument dilutions and manual pre-dilutions where validated.
ANALYSER
Binding Site Optilite®
DESCRIPTION Freelite Kappa Latex kit
Range 2.9-127 mg/L, sensitivity 0.6 mg/L
Freelite Lambda Latex kit 100 test LK018.OPT Range 5.2-139 mg/L, sensitivity 1.3 mg/L
Freelite Kappa Latex kit
Binding Site SPAPLUS®
Range 4.0-180 mg/L, sensitivity 0.4 mg/L
Freelite Lambda Latex kit 100 test LK018.S Range 4.5-165 mg/L, sensitivity 0.45 mg/L
Freelite Kappa Latex kit
Freelite rapidly quantifies free light chains (FLCs) to aid in the diagnosis, prognosis and monitoring of monoclonal gammopathies.
Affinity purified polyclonal antibodies, reacting specifically with and FLCs, are pre-coated onto latex particles. These latex reagents are used to produce nephelometric and turbidimetric kits that are specific for FLCs.
IMWG* recommend Freelite for use:1
• At diagnosis - to confirm disease state • For prognosis - to predict patient outcomes • When monitoring - to measure response to treatment
Freelite CSF
During inflammation of the central nervous system, immunoglobulins synthesised intrathecally gradually accumulate in the cerebrospinal fluid (CSF).2
measurement in CSF. Freelite CSF Free Light Chain Assays ANALYSER
Binding Site SPAPLUS®
DESCRIPTION PACK CODE
Freelite Kappa Latex kit 100 test LK016.L.S Range 0.1-18 (mg/L), sensitivity 0.1 (mg/L) Freelite Lambda Latex kit 100 test LK018.L.S Range 0.1-16.5 (mg/L), sensitivity 0.1 (mg/L)
Siemens BNTM
II
Freelite Kappa Latex kit 2x50 test LK016.L.T Range 0.06-1.9 (mg/L), sensitivity 0.06 (mg/L) Freelite Lambda Latex kit 2x50 test LK018.L.T Range 0.05-1.6 (mg/L), sensitivity 0.05 (mg/L)
Kits also for use with serum and urine.
Siemens BN ProSpec®
Freelite kits are available for free light chain
Beckman IMMAGE®
Range 6-180 mg/L, sensitivity 3 mg/L
Freelite Lambda Latex kit 2x50 test
LK018.IM Range 4.8-162 mg/L, sensitivity 2.4 mg/L
Freelite Kappa Latex kit
Roche Hitachi 911/912/917/
Range 3.7-56.2 mg/L, sensitivity 0.8 mg/L
Freelite Lambda Latex kit 2x50 test LK018.H Range 5.6-74.8 mg/L, sensitivity 0.7 mg/L
Freelite Kappa Latex kit
Roche Cobas Integra®
400plus/800 400/
Range 2.9-127 mg/L, sensitivity 0.6 mg/L
Freelite Lambda Latex kit 100 test LK018.RI Range 5.2-139 mg/L, sensitivity 1.3 mg/L
Freelite Kappa Latex kit
Roche cobas® c Systems
100 test LK016.CB
Range 3.7-56.2 (mg/L), sensitivity 0.8 (mg/L) Freelite Lambda Latex kit 100 test LK018.CB Range 5.6-74.8 (mg/L), sensitivity 0.7 (mg/L)
Freelite Kappa Latex kit
Siemens BNTM
II
Range 5.9-190 mg/L, sensitivity 0.3 mg/L
Freelite Lambda Latex kit 2x50 test LK018.T Range 5-160 mg/L, sensitivity 0.25 mg/L
Freelite Kappa Latex kit
Range 5.9-190 mg/L, sensitivity 0.3 mg/L
Freelite Lambda Latex kit 2x50 test LK018.P Range 5-160 mg/L, sensitivity 0.25 mg/L
*Kit also available for use with urine. Ranges and sensitivity remain the same. Please use code LK016.U.OPT.
**Kit also available for use with urine. Ranges and sensitivity remain the same. Please use code LK018.U.OPT.
2x50 test LK016.P 2x50 test LK016.T 100 test LK016.RI 2x50 test LK016.H 2x50 test
LK016.IM 100 test LK016.S ** PACK 100 test CODE LK016.OPT *
Want to learn more? Professor Sigurdur Kristinsson discusses the ‘iStopMM’ screening study
* International Myeloma Working Group 10 More information at:
www.bindingsite.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28